Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A78-202    Drive Motor "A" Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A78
202
Malfunction (short circuit) in the motor inverter inside the inverter with converter assembly
Current flowing to any of the phases exceeds a certain level after a DTC (indicates a motor inverter malfunction: overheating, overcurrent or circuit malfunction) is stored and the motor inverter is shutdown
(1 trip detection logic)
  1. Inverter with converter assembly
  2. Hybrid vehicle transaxle assembly
  3. Motor cable

MONITOR DESCRIPTION

The MG ECU monitors the motor inverter electric current. If the current exceeds the threshold for a specified period of time, the power management control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A78 (INF 202): MFIV detection (Short circuit malfunction)
Required sensors / components
Motor inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU
DTC P0A78 (INF 202) is not detected

CONFIRMATION DRIVING PATTERN


A310322E02

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off and wait for 30 seconds or more.
  5. Turn the ignition switch to ON (IG) and turn the Techstream on.
  6. Turn the ignition switch to ON (READY).
  7. With the shift lever in P, and engine stopped, depress the accelerator pedal to start the engine. [A]

    HINT:
    Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc).

  8. Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes. [B]
  9. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  10. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  11. Check that permanent DTCs are cleared. If no permanent DTC is output, the system is normal.
  12. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  2. DTC P0A78-202 is stored after any of DTCs P0A78-113, 284, 286, 287, 505 and 506 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
  3. Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
  4. After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h (25 mph) for 1 minute and check that DTC P0A90-251 (Drive Motor "A" Performance) is not output. If DTC P0A90-251 (Drive Motor "A" Performance) is output, replace the hybrid vehicle transaxle assembly.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. With the vehicle engine stopped, the ignition switch to ON (READY) and the shift lever in P, depress the accelerator pedal to start the engine.
  2. Perform a road test according to the freeze frame data and item "Vehicle Spd" for approximately 10 minutes.

1.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258648
  1. Disconnect the motor cable from the inverter with converter assembly.



    A268151E05
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a4-1 (W) - a4-2 (U)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-2 (U) - a4-3 (V)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-3 (V) - a4-1 (W)
      Ignition switch off
      172.5 to 190.7 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable (for MG2)
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
Go to step 4
OK


2.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT


3.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Check the other DTCs that were output together with DTC P0A78-202.

    Result:

    DTC No.
    Relevant Diagnosis
    P0A78-113, 284, 286, 287, 505, 506
    Drive Motor "A" Inverter Performance

    NOTICE:
    DTC P0A78-202 is stored after any of DTCs P0A78-113, 284, 286, 287, 505 and 506 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.


NEXT

GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)  

4.CHECK MOTOR CABLE (FOR MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable (Click here).



    A258651E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield ground
    *a
    Motor Cable (for MG2)
    (Inverter with Converter Assembly Side)
    *b
    Motor Cable (for MG2)
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the motor cable (for MG2) with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - a3-1 (W)
    Ignition switch off
    Below 1 Ω
    a4-2 (U) - a3-3 (U)
    Ignition switch off
    Below 1 Ω
    a4-3 (V) - a3-2 (V)
    Ignition switch off
    Below 1 Ω
    a4-1 (W) - a3-3 (U)
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - a3-2 (V)
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - a3-1 (W)
    Ignition switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
Go to step 8
OK


5.REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
(Click here)

NEXT


6.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT


7.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Check the other DTCs that were output together with DTC P0A78-202.

    Result:

    DTC No.
    Relevant Diagnosis
    P0A78-113, 284, 286, 287, 505, 506
    Drive Motor "A" Inverter Performance

    NOTICE:
    DTC P0A78-202 is stored after any of DTCs P0A78-113, 284, 286, 287, 505 and 506 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.


NEXT

GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)  

8.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.



    A267469E01
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a3-1 (W) - a3-3 (U)
      Ignition switch off
      170.3 to 188.1 mΩ
      a3-2 (V) - a3-1 (W)
      Ignition switch off
      170.3 to 188.1 mΩ
      a3-3 (U) - a3-2 (V)
      Ignition switch off
      170.3 to 188.1 mΩ

      Text in Illustration 
      *a
      Component without motor cable (for MG2) connected
      (Hybrid Vehicle Transaxle Assembly)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (° C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a3-1 (W) - Body ground
    Ignition switch off
    100 MΩ or higher
    a3-2 (V) - Body ground
    Ignition switch off
    100 MΩ or higher
    a3-3 (U) - Body ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable (for MG2).



NG
Go to step 12
OK


9.REPLACE MOTOR CABLE
(Click here)

NEXT


10.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT


11.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Check the other DTCs that were output together with DTC P0A78-202.

    Result:

    DTC No.
    Relevant Diagnosis
    P0A78-113, 284, 286, 287, 505, 506
    Drive Motor "A" Inverter Performance

    NOTICE:
    DTC P0A78-202 is stored after any of DTCs P0A78-113, 284, 286, 287, 505 and 506 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.


NEXT

GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)  

12.REPLACE MOTOR CABLE
(Click here)

NEXT


13.REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
(Click here)

NEXT


14.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT


15.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Check the other DTCs that were output together with DTC P0A78-202.

    Result:

    DTC No.
    Relevant Diagnosis
    P0A78-113, 284, 286, 287, 505, 506
    Drive Motor "A" Inverter Performance

    NOTICE:
    DTC P0A78-202 is stored after any of DTCs P0A78-113, 284, 286, 287, 505 and 506 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.


NEXT

GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)