HAZARD WARNING SWITCH > REMOVAL |
| 1. REMOVE CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY |
![]() |
Apply protective tape to the area shown in the illustration.
| *1 | Protective Tape |
![]() |
Using a moulding remover, disengage the 8 clips and claw.
Disconnect the connector and remove the center instrument cluster finish panel sub-assembly.
| 2. REMOVE HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
![]() |
Disengage the 2 claws and remove the hazard warning signal switch assembly from the center instrument cluster finish panel sub-assembly.