REFRIGERANT LINE > REMOVAL |
| 1. RECOVER REFRIGERANT FROM AIR CONDITIONING SYSTEM |
Start the hybrid system.
Operate the cooler compressor under the conditions show below:
| Item | Condition |
| Engine Speed | Idling |
| Operating Time | 3 minutes or more |
| A/C Switch Status | ON |
| Blower Switch Status | HI |
| Set Temperature | MAX COOL |
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. REMOVE NO. 1 AIR CLEANER INLET |
![]() |
Remove the bolt and No. 1 air cleaner inlet.
| 3. REMOVE PIPING CLAMP |
While pressing the end of the suction hose sub-assembly into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.

| *1 | Suction Pipe Sub-assembly | *2 | Suction Hose Sub-assembly |
| *3 | Piping Clamp | - | - |
| *a | Press In | - | - |
Separate the suction hose sub-assembly.
Remove the 2 O-rings from the suction hose sub-assembly.