Home › Engine / Hybrid System › 1NZ-FXE EMISSION CONTROL › VACUUM SENSOR

VACUUM SENSOR > REMOVAL

for Preparation Click here



1. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    A267396
  1. Disconnect the ventilation hose.



    A267397
  1. Disconnect the purge VSV.



    A267398
  1. Disconnect the mass air flow meter connector.

  1. Disconnect the wire harness clamp.

  1. Release the 2 clamps.



    A267400
  1. Loosen the hose clamp and remove the air cleaner cap sub-assembly.



2. REMOVE AIR CLEANER CASE SUB-ASSEMBLY
  1. Remove the air cleaner filter element sub-assembly.



    A267683
  1. Remove the 2 bolts, grommet and air cleaner case sub-assembly.



3. REMOVE MANIFOLD ABSOLUTE PRESSURE SENSOR


    A267675
  1. Disconnect the connector.

  1. Remove the bolt and manifold absolute pressure sensor.