Home › Drivetrain › P510 HYBRID TRANSMISSION / TRANSAXLE › MOTOR CABLE

MOTOR CABLE > INSTALLATION

for Preparation Click here



1. INSTALL MOTOR CABLE

CAUTION:
Wear insulated gloves.



  1. Install the motor cable (for MG 1).

    1. Install the motor cable to the hybrid vehicle transaxle assembly with the 3 bolts.

      Torque:
      10 N*m{ 102 kgf*cm , 7 ft.*lbf }

      NOTICE:
      Keep the sealing surface of the generator cable and the connector terminal joint free of foreign matter.

    2. Engage the 2 claws to install a new terminal cap to the hybrid vehicle transaxle assembly.

      NOTICE:
      1. Keep foreign matter, water, etc. away from the terminal cap and its installation section.
      2. Do not pinch the O-ring.
      3. Check that the terminal cap is securely installed.



    3. C251935
    4. Place the connector shell in position and install it with the 2 bolts.

      Torque:
      19 N*m{ 196 kgf*cm , 14 ft.*lbf }



  1. Install the motor cable (for MG 2).

    1. Install the motor cable to the hybrid vehicle transaxle assembly with the 3 bolts.

      Torque:
      10 N*m{ 102 kgf*cm , 7 ft.*lbf }

      NOTICE:
      Keep the sealing surface of the generator cable and the connector terminal joint free of foreign matter.

    2. Engage the 2 claws to install a new terminal cap to the hybrid vehicle transaxle assembly.

      NOTICE:
      1. Keep foreign matter, water, etc. away from the terminal cap and its installation section.
      2. Do not pinch the O-ring.
      3. Check that the terminal cap is securely installed.



    3. C251936
    4. Place the connector shell in position and install it with the 2 bolts.

      Torque:
      19 N*m{ 196 kgf*cm , 14 ft.*lbf }

  1. Connect the 4 clamps and install the motor cable to the hybrid vehicle transaxle assembly.



2. CONNECT WIRE HARNESS
  1. Connect the clamp and install the wire harness to the hybrid vehicle transaxle assembly with the 2 bolts.

    Torque:
    13 N*m{ 130 kgf*cm , 9 ft.*lbf }

  1. Connect the 3 clamps and install the No. 2 engine wire to the hybrid vehicle transaxle assembly.



3. CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
  1. Connect the transmission control cable assembly to the transmission control cable clamp and transmission control cable support.



4. INSTALL INVERTER BRACKET ASSEMBLY

CAUTION:
Wear insulated gloves.

  1. Temporarily install the inverter bracket assembly with the 4 bolts.



    A268009E01
  1. Tighten the 4 bolts in the sequence shown in the illustration.

    Torque:
    21 N*m{ 214 kgf*cm , 15 ft.*lbf }

  1. Connect the earth wire with the bolt.

    Torque:
    8.4 N*m{ 85 kgf*cm , 74 in.*lbf }

  1. Install the inverter reservoir tank assembly with the 2 bolts.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }



    A268006
  1. Connect the 2 wire harness clamps.



    A268005
  1. Connect the motor cable protector with the bolt.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }



5. INSTALL INVERTER WITH CONVERTER ASSEMBLY
(Click here)