DTC P0A78-565 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 565 | Motor inverter overvoltage signal is detected (VH sensor circuit malfunction) and voltage after boosting does not change for a certain period of time. (1 trip detection logic) | Inverter with converter assembly |
| DTC No. | Data List |
| P0A78-565 | VH-Voltage after Boosting |
| Related DTCs | P0A78 (INF 565): OVH detection (Voltage (VH) sensor malfunction) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU | DTC P0A78 (INF 565) is not detected |

| 1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | ||
| ||