HYBRID / BATTERY CONTROL > SERVICE DATA |
| Item | Specified Condition |
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Item | Tester Connection | Specified Condition |
| IGCT relay Resistance | 3 - 5 | 10 kΩ or higher (No auxiliary battery voltage is applied across terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Auxiliary battery voltage is applied across terminals 1 and 2) |
| SMRB Resistance | A-1 (+) - P5-1 (CBI) | 10 kΩ or higher (Auxiliary battery voltage is not applied between terminals M40- 1 (SMRB) and M40-2 (GND)) |
| Below 1 Ω (Auxiliary battery voltage is applied between terminals M40- 1 (SMRB) and M40-2 (GND)) | ||
| M40-1 (SMRB) - M40-2 (GND) | 25.0 to 59.0 Ω (at -40 to 80°C (-40 to 176°F)) | |
| SMRG Resistance | c1-1 (-) - P4-1 (CEI) | 10 kΩ or higher (Auxiliary battery voltage is not applied between terminals M40- 3 (SMRG) and M40-2 (GND)) |
| Below 1 Ω (Auxiliary battery voltage is applied between terminals M40- 3 (SMRG) and M40-2 (GND)) | ||
| M40-3 (SMRG) - M40-2 (GND) | 25.0 to 59.0 Ω (at -40 to 80°C (-40 to 176°F)) | |
| SMRP Resistance | P4-1 (CEI) - c1-1 (-) | 10 kΩ or higher (Auxiliary battery voltage is not applied between terminals M40- 4 (SMRP) and M40-2 (GND)) |
| 28.5 to 31.5 Ω (Auxiliary battery voltage is applied between terminals M40- 4 (SMRP) and M40-2 (GND)) | ||
| M40-4 (SMRP) - M40-2 (GND) | 112 to 274 Ω (at -40 to 80°C (-40 to 176°F)) |
| Service plug grip | Always | Below 1 Ω |
| EV drive mode switch (pattern select switch assembly) | G63-4 (S) - G63-1 (E) | Below 1 Ω (EV drive mode switch (pattern select switch assembly) being pushed and held) |
| 10 kΩ or higher (EV drive mode switch (pattern select switch assembly) not pushed) | ||
| Illumination | Auxiliary battery positive (+) → G63-3 (ILL+) Auxiliary battery negative (-) →G63-2 (ILL-) | Illuminates |