ROOM TEMPERATURE SENSOR > INSTALLATION |
| 1. INSTALL ROOM TEMPERATURE SENSOR (COOLER THERMISTOR) |
Connect the connector and aspirator.
![]() |
Engage the 2 claws to install the room temperature sensor (cooler thermistor).
| 2. INSTALL AIR CONDITIONING CONTROL ASSEMBLY |
Connect the connector.
Engage the 4 clips to install the air conditioning control assembly.
| 3. INSTALL LOWER INSTRUMENT CLUSTER FINISH PANEL GARNISH |
Engage the 3 claws, 8 clips and 3 guides to install the lower instrument cluster finish panel garnish.
| 4. INSTALL INSTRUMENT CLUSTER FINISH PANEL GARNISH |
![]() |
Engage the 10 guides and 12 clips to install the instrument cluster finish panel garnish.
| 5. INSTALL NO. 2 INSTRUMENT PANEL REGISTER ASSEMBLY |
Engage the 3 clips to install the No. 2 instrument panel register assembly.
| 6. INSTALL CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY |
![]() |
Engage the claw and 8 clips to install the center instrument cluster finish panel sub-assembly.