Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

HYBRID BATTERY SYSTEM > TERMINALS OF ECU

for Preparation Click here



A244305E02


Text in Illustration 
*1
Battery Smart Unit
-
-

ECU TERMINAL CHART 
Terminal No.
(Symbols)
Wiring Color
Terminal Description
Condition
Standard (V)
d1-2 (TB2) - d1-8 (GB2)
L - L
Battery temperature sensor 2
HV battery temperature: -40 to 90 °C (-40 to 194 °F)
4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
d1-3 (TB1) - d1-9 (GB1)
W - W
Battery temperature sensor 1
HV battery temperature: -40 to 90 °C (-40 to 194 °F)
4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
d1-4 (TBO) - d1-10 (GBO)
R - R
Battery temperature sensor 0
HV battery temperature: -40 to 90 °C (-40 to 194 °F)
4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
d1-5 (IB) - d1-12 (GIB)
Y - B
Current sensor
Ignition switch ON (READY)
0.5 to 4.5
d1-6 (VIB) - d1-12 (GIB)
BR - B
Power source for battery current sensor
Ignition switch ON (IG)
4.5 to 5.5
M39-3 (IGCT) - M39-6 (GND)
L - W-B
Control signal
Ignition switch ON (READY)
11 to 14
M39-1 (BTH+) - M39-6 (GND)
R - W-B
Serial communication
Ignition switch ON (IG)
Pulse generation
(waveform 1)
M39-4 (BTH-) - M39-6 (GND)
G - W-B
Serial communication
Ignition switch ON (IG)
Pulse generation
(waveform 2)
M39-5 (FP0) - M39-6 (GND)
B - W-B
Battery cooling blower No. 0 monitor signal
Cooling blower activated
Pulse generation
M39-6 (GND) - Body ground
W-B
Ground
Always (continuity check)
Below 1 Ω

Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    A112888E01
  1. Waveform 1
    Item
    Content
    Terminal
    M39-1 (BTH+) - M39-6 (GND)
    Equipment Setting
    2 V/DIV., 500 μs/DIV.
    Condition
    Ignition switch ON (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  2. A112889E01
  3. Waveform 2
    Item
    Content
    Terminal
    M39-4 (BTH-) - M39-6 (GND)
    Equipment Setting
    2 V/DIV., 500 μs/DIV.
    Condition
    Ignition switch ON (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).