DTC    P0AA1-233    Hybrid Battery Positive Contactor Circuit Stuck Closed

for Preparation Click here


DESCRIPTION

  1. Refer to the description for DTC P0AE6-225 .
  2. This circuit uses the power management control ECU to monitor the system main relays and stops the system if a malfunction is detected in the relays, because it may be impossible to shut off the high-voltage system if any of the relays becomes stuck.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0AA1
233
System main relay stuck closed error (HV battery positive (+) and negative (-) terminal side)
(1 trip detection logic)
  1. Hybrid battery junction block assembly
  2. Inverter with converter assembly

Related Data List 
DTC No.
Data List
P0AA1-233
  1. Power Resource VB
  2. VH-Voltage after Boosting
The following items can be helpful when performing repairs:
Data List
  1. SMRP Status
  2. SMRB Status
  3. SMRG Status

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 .

INSPECTION PROCEDURE

CAUTION:
  1. When performing P0AA1-233 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
  2. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  3. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
  1. If P0AA1-233 is stored, the hybrid system cannot be turned on (READY).
  2. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Turn the ignition switch off and wait for 30 seconds or more.
    2. Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
    3. Turn the ignition switch off and wait for 30 seconds or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Only P0AA1-233 is output or P0AA1-233 and DTCs other than the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793
    Generator Control Module
    P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796
    Drive Motor "A" Control Module
    P0A1D-148
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A78-266, 267, 586
    Drive Motor "A" Inverter Performance
    P0A94-442
    DC / DC Converter Performance
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P2511-149
    ECM/PCM Power Relay Sensor Circuit Intermittent
    P3004-132
    High Voltage Power Resource
    P324E-788
    MG-ECU Power Relay Intermittent Circuit
    U0110 (all INF codes)*1
    Lost Communication with Drive Motor Control Module "A"

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0AA1-233 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.

  1. Turn the ignition switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


2.CHECK FREEZE FRAME DATA (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Read the freeze frame data of DTC P0AA1-233.

    Result:

    Result
    Proceed to
    VH-Voltage after Boosting minus VL-Voltage before Boosting is 100 V or less.
    A
    The preceding condition is not satisfied.
    B

  1. Turn the ignition switch off.



B
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
A


3.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 2 hybrid battery shield sub-assembly .



    A267577E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (SMRB):
    Tester Connection
    Switch Condition
    Specified Condition
    P5-1 (CBI) - A-1 (+)
    Ignition switch off
    10 kΩ or higher

    HINT:
    1. If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
    2. If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.



    A267578E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (SMRG, SMRP):
    Tester Connection
    Switch Condition
    Specified Condition
    P4-1 (CEI) - c1-1 (-)
    Ignition switch off
    10 kΩ or higher

    HINT:
    1. If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
    2. If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
    3. If the resistance is between 28.5 and 31.5 Ω, it can be determined that SMRP is stuck closed.

  1. Install the No. 2 hybrid battery shield sub-assembly.



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)