LIGHTING SYSTEM > CUSTOMIZE PARAMETERS |
| CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Customize Setting / Illuminated Entry.
Select the setting by referring to the table below.
| Tester Display | Default | Content | Setting | Relevant ECU |
| Lighting Time | 15 s | Changes the lighting time after closing all of the doors. (It will fade out immediately in case of turning the power switch from off to on (ACC or IG).) | 7.5 s, 15 s or 30 s | Main body ECU (Multiplex network body ECU) |
| I/L when ACC OFF | ON | Lights up power switch illumination, front interior lights, rear interior light and footwell lights when the power switch is turned from on (ACC or IG) to off. | ON or OFF | |
| I/L ON W/Door Key Unlock | ON | Lights up power switch illumination, front interior lights, rear interior light and footwell lights when doors are unlocked using a mechanical key or door control transmitter. | ON or OFF | |
| Light Control | ON | Dims (ON setting) or turns off (OFF setting) the footwell lights under the following conditions: Power switch on (IG), shift lever not in P, and all doors closed. | ON or OFF | |
| Room Light when Aprchd | ON | Lights up the power switch illumination, front interior lights, rear interior light and footwell lights when a key enters any actuation area around the doors. | ON or OFF | |
| Inside Foot Light | ON | ON/OFF of footwell light control function. | ON or OFF |
| CUSTOMIZING FUNCTION WITH MULTI-DISPLAY (for Navigation Receiver Type) |
Turn the power switch on (IG).
Enter the following menus: Setup / Vehicle / Vehicle Customization / Light Settings.
Select the setting by referring to the table below:
| Display | Default | Content | Setting | Relevant ECU |
| Interior Lights Off Timer | 15 sec. | Changes the lighting time after closing all of the doors. (It will fade out immediately in case of turning the power switch from off to on (ACC or ON).) | Off, 7.5 sec., 15 sec., or 30 sec. | Main body ECU (Multiplex network body ECU) |