Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > Blower Motor Circuit

for Preparation Click here


DESCRIPTION

The blower motor is operated by signals from the A/C amplifier. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM


w/o Solar Ventilation System

E191583E01


w/ Solar Ventilation System

E191584E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Air Conditioner / Active Test.

  1. Check the operation by referring to the table below.


Air Conditioner 
Tester Display
Test Part
Control Range
Diagnostic Note
Blower Motor
Blower motor
Min.: 0, Max.: 31
-

OK:
Blower motor operates and blower motor speed level changes.


Result:

Result
Proceed to
OK
A
NG (Blower motor does not operate)
(w/o Solar ventilation system)
B
NG (Blower motor does not operate)
(w/ Solar ventilation system)
C
NG (Blower motor operates but does not change speed)
(w/o Solar ventilation system)
D
NG (Blower motor operates but does not change speed)
(w/ Solar ventilation system)
E



B
Go to step 2

C
Go to step 7

D
Go to step 6

E
Go to step 12
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)


    E161718E26
  1. Disconnect the blower motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L33-1 (GND) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)


    E161718E27
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L33-3 (+B) - Body ground
    Power switch off
    11 to 14 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - A/C AMPLIFIER)


    E177002E66
  1. Disconnect the A/C amplifier connector.



    E161718E28
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L17-23 (BLW) - L33-2 (SI)
    Always
    Below 1 Ω
    L17-23 (BLW) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to A/C Amplifier)
    *2
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT BLOWER MOTOR
  1. Reconnect the blower motor connector.



    E177002E67
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L17-23 (BLW) - Body ground
    Power switch off
    4.5 to 5.5 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to A/C Amplifier)



NG
REPLACE BLOWER MOTOR (Click here)
OK


6.INSPECT A/C AMPLIFIER


    E127604E20
  1. Remove the A/C amplifier.

  1. Reconnect the A/C amplifier connector.

  1. Turn the power switch on (IG).

  1. Set the blower speed to LO.

  1. Measure the waveform between terminal L17-23 (BLW) of the A/C amplifier and body ground.
    Item
    Content
    Tool setting
    1 V/DIV., 500 μs/DIV.
    Vehicle condition
    Power switch on (IG)
    Blower set to LO

    OK:
    Waveform is as shown in the illustration.

    HINT:
    The waveform varies with the blower speed.

    Text in Illustration 
    *1
    Component with harness connected
    (A/C Amplifier)



NG
REPLACE A/C AMPLIFIER (Click here)
OK

REPLACE BLOWER MOTOR (Click here)  

7.INSPECT SOLAR VENTILATION RELAY


    E188585
  1. Remove the solar ventilation relay from the relay block No. 2-1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 4
    Below 1 Ω
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)
    3 - 4
    10 kΩ or higher
    (when battery voltage is applied to terminals 1 and 2)



NG
REPLACE SOLAR VENTILATION RELAY
OK


8.CHECK HARNESS AND CONNECTOR (RELAY BLOCK NO. 2-1 - BATTERY)


    E190426E01
  1. Disconnect the relay block No. 2-1 connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L104-1 - Body ground
    Power switch off or on (ACC)
    Below 1 V
    L104-1 - Body ground
    Power switch on (IG)
    11 to 14 V
    L104-5 - Body ground
    Always
    11 to 14 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Relay Block No. 2-1)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HARNESS AND CONNECTOR (RELAY BLOCK NO. 2-1 - BODY GROUND)


    E190426E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L104-2 - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Relay Block No. 2-1)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)


    E161718E26
  1. Disconnect the blower motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L33-1 (GND) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)
  1. Reinstall the solar ventilation relay to the relay block No. 2-1.



    E161718E27
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L33-3 (+B) - Body ground
    Power switch off or on (ACC)
    Below 1 V
    L33-3 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (BLOWER MOTOR - RELAY BLOCK NO. 2-1)
OK


12.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - A/C AMPLIFIER)


    E177002E66
  1. Disconnect the A/C amplifier connector.



    E190424E10
  1. Disconnect the solar ventilation ECU connector.



    E161718E28
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L17-23 (BLW) - L33-2 (SI)
    Always
    Below 1 Ω
    L17-23 (BLW) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to A/C Amplifier)
    *2
    Front view of wire harness connector
    (to Solar Ventilation ECU)
    *3
    Front view of wire harness connector
    (to Blower Motor)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


13.INSPECT BLOWER MOTOR
  1. Reconnect the blower motor connector.



    E177002E67
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L17-23 (BLW) - Body ground
    Power switch off or on (ACC)
    Below 1 V
    L17-23 (BLW) - Body ground
    Power switch on (IG)
    4.5 to 5.5 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to A/C Amplifier)



NG
REPLACE BLOWER MOTOR (Click here)
OK


14.INSPECT A/C AMPLIFIER


    E127604E20
  1. Remove the A/C amplifier.

  1. Reconnect the A/C amplifier connector.

  1. Turn the power switch on (IG).

  1. Set the blower speed to LO.

  1. Measure the waveform between terminal L17-23 (BLW) of the A/C amplifier and body ground.
    Item
    Content
    Tool setting
    1 V/DIV., 500 μs/DIV.
    Vehicle condition
    Power switch on (IG)
    Blower set to LO

    OK:
    Waveform is as shown in the illustration.

    HINT:
    The waveform varies with the blower speed.

    Text in Illustration 
    *1
    Component with harness connected
    (A/C Amplifier)



NG
REPLACE A/C AMPLIFIER (Click here)
OK

REPLACE BLOWER MOTOR (Click here)