Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › ENTRY AND START SYSTEM (for Start Function)

DTC    B2271    Ignition Hold Monitor Malfunction

for Preparation Click here


DESCRIPTION

This DTC is stored when a problem such as an open in the AM2 fuse, an open or short in the wire harness between the fuse and power management control ECU, a short in the IG output circuit inside the power management control ECU, a short between the power management control ECU and relay, or a short in the relay is detected.

DTC No.
DTC Detection Condition
Trouble Area
B2271
The hold circuit, IG1 relay actuation circuit or IG2 relay actuation circuit inside the power management control ECU is open or shorted.
  1. AM2 fuse
  2. IG1 relays
  3. IG2 relay
  4. Power management control ECU
  5. Instrument panel junction block assembly
  6. Wire harness or connector

WIRING DIAGRAM


B231372E01


INSPECTION PROCEDURE

NOTICE:
  1. When the power management control ECU is replaced with a new one and the cable from the negative (-) auxiliary battery terminal is connected, the power source mode becomes on (IG) mode. When the auxiliary battery is removed and reinstalled, the power source mode that was selected when the auxiliary battery was removed is restored.
  2. Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)
  1. Disconnect the L5 and L6 connectors from the power management control ECU.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    L5-1 (AM22) - Body ground
    Always
    9.5 to 16 V
    L6-7 (AM21) - Body ground
    Always
    9.5 to 16 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)
OK


2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L5-5 (E01) - Body ground
    Always
    Below 1 Ω
    L5-6 (E1) - Body ground
    Always
    Below 1 Ω
    L6-4 (E12) - Body ground
    Always
    Below 1 Ω
    L6-5 (E02) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
OK


3.INSPECT IG2 RELAY


    A172755E08
  1. Remove the engine room relay block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1A-2 - 1A-3
    20°C (68°F)
    130 to 230 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (Engine Room Relay Block)



NG
REPLACE IG2 RELAY
OK


4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG1 NO. 1, IG1 NO. 2 AND IG1 NO. 3 RELAYS)


    B231373E01
  1. Remove the instrument panel junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2B-25 - 2B-4
    20°C (68°F)
    52.32 to 79.32 Ω
    2B-25 - 2B-6
    20°C (68°F)
    52.32 to 79.32 Ω
    2B-4 - 2B-6
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (Instrument Panel Junction Block Assembly)



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL J/B)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L6-2 (IG1D) - 2B-25
    Always
    Below 1 Ω
    L6-2 (IG1D) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2B-4 - Body ground
    Always
    Below 1 Ω
    2B-6 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
OK


7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A22-2 (IG2D) - 1A-2
    Always
    Below 1 Ω
    A22-2 (IG2D) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)
OK


8.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK ASSEMBLY - BODY GROUND)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1A-3 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ENGINE ROOM RELAY BLOCK ASSEMBLY - BODY GROUND)
OK


9.CHECK POWER MANAGEMENT CONTROL ECU


    B229525E03
  1. Install the instrument panel junction block assembly.

  1. Install the engine room relay block.

  1. Reconnect the A22 and L6 connectors.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A22-2 (IG2D) - Body ground
    Power switch on (IG)
    Output voltage at terminal AM21 or AM22 is -2.5 V or more
    L6-2 (IG1D) - Body ground
    Power switch on (IG)
    Output voltage at terminal AM21 or AM22 is -2.5 V or more

    Text in Illustration 
    *1
    Component with harness connected
    (Power Management Control ECU)



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK

USE SIMULATION METHOD TO CHECK (Click here)