Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A78-510    Drive Motor "A" Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter, .
If the inverter receives a motor gate shutdown signal from the MG ECU, it will turn all power transistors off which are activating MG2 to forcibly stop MG2 operation.
The MG ECU monitors motor gate shutdown signals and detects a malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A78
510
Motor inverter gate malfunction
Inverter with converter assembly

HINT:
  1. When P0A78-510 has been stored, the hybrid system cannot be restarted until the DTC is cleared.
  2. If the problem symptom cannot be reproduced, leaving the vehicle with the power switch on (READY) and the selector lever in N for 1 minute will make it easier to reproduce the symptom.


INSPECTION PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
A214648

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

  1. Check the connection of the low voltage connector of the inverter with converter assembly.

    OK:
    The connector is connected securely and there are no contact problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)