LIGHTING SYSTEM > Daytime Running Light Relay Circuit |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Active Test.
Check that the daytime running lights operate.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Daytime Running Light | Daytime running lights | ON/OFF | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT RUNNING LIGHT RELAY |
![]() |
Remove the running light relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage is applied between terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BATTERY - RUNNING LIGHT RELAY) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Running light relay terminal 1 - Body ground | Always | 11 to 14 V |
| Running light relay terminal 3 - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (RUNNING LIGHT RELAY - MAIN BODY ECU) |
Disconnect the L7 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Running light relay terminal 2 - L7-15 (DRLE) | Always | Below 1 Ω |
| L7-15 (DRLE) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||