REFRIGERANT > ON-VEHICLE INSPECTION |
| 1. INSPECT REFRIGERANT VOLUME |
![]() |
Check the sight glass on the air conditioning tube and accessory.
Prepare the vehicle according to the chart below.
| Item | Condition |
| Vehicle door | Fully open |
| Temperature setting | MAX COOL |
| Blower speed | HI |
| A/C | on |
Compare the sight glass to the following chart.
| Item | Symptom | Amount of Refrigerant | Corrective Action |
| 1 | Bubbles exist | Insufficient* |
|
| 2 | No bubbles exist | Empty, insufficient, or excessive | Refer to 3 and 4 |
| 3 | No temperature difference between compressor inlet and outlet | Empty or nearly empty |
|
| 4 | Considerable temperature difference between compressor inlet and outlet | Proper or excessive | Refer to 5 and 6 |
| 5 | Immediately after air conditioning is turned off, refrigerant remains clear | Excessive |
|
| 6 | Immediately after air conditioning is turned off, refrigerant foams and then becomes clear | Proper | - |
| 2. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
Read the manifold gauge pressure when the following conditions are met:
Test conditions:
![]() |
Normally functioning refrigeration system
| Pressure Side | Refrigerant Volume |
| Low | 0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21 to 36 psi) |
| High | 1.37 to 1.57 MPa (13.9 to 16.0 kgf/cm2, 199 to 228 psi) |
Moisture is present in the refrigeration system.

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| During operation, pressure on low pressure side cycles between normal and vacuum |
|
|
|
Insufficient cooling

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| Gas leaks from the refrigeration system |
|
|
Poor circulation of refrigerant

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| Refrigerant flow is obstructed by dirt inside the pipes of the condenser core | Receiver is clogged | Replace condenser |
Refrigerant does not circulate.

| Symptom | Probable Cause | Diagnosis | Corrective Action |
|
| Refrigerant does not circulate |
|
Refrigerant is overcharged or cooling effectiveness of condenser is insufficient.

| Symptom | Probable Cause | Diagnosis | Corrective Action |
|
|
|
|
Air is present in the refrigeration system.

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| Air in system |
|
|
Expansion valve malfunction

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| Expansion valve may be stuck |
| Check expansion valve |
Insufficient compressor compression

| Symptom | Probable Cause | Diagnosis | Corrective Action |
| Internal leak in compressor |
| Replace compressor |