BRAKE PEDAL STROKE SENSOR (for LHD) > INSTALLATION |
| 1. INSTALL BRAKE PEDAL STROKE SENSOR ASSEMBLY |
When installing a new brake pedal stroke sensor assembly:
![]() |
Temporarily install a new brake pedal stroke sensor assembly with the 2 nuts.
| *1 | Brake Pedal Groove |
| *2 | Brake Pedal Stroke Sensor Assembly Lever |
When reusing the brake pedal stroke sensor assembly:
![]() |
Temporarily install the brake pedal stroke sensor assembly with the 2 nuts.
| *1 | Brake Pedal Groove |
| *2 | Brake Pedal Stroke Sensor Assembly Lever |
| 2. INSTALL BRAKE PEDAL SUPPORT ASSEMBLY |
| 3. INSPECT AND ADJUST BRAKE PEDAL |
Check the brake pedal height.
Turn back the carpet.
Turn back the dash silencer from the slit provided on the dash silencer.
![]() |
Measure the shortest distance between the brake pedal surface and floor panel.
| *1 | Stop Light Switch Assembly |
| *2 | Clevis Lock Nut |
| *3 | Floor Panel |
| *4 | Brake Pedal Height |
Adjust the brake pedal height.
Remove the stop light switch assembly (Click here).
Loosen the clevis lock nut.
Adjust the brake pedal height by turning the push rod.
Tighten the clevis lock nut.
Install and adjust the stop light switch assembly (Click here).
| 4. ADJUST BRAKE PEDAL STROKE SENSOR ASSEMBLY |
When installing a new brake pedal stroke sensor assembly:
![]() |
Fully tighten a new brake pedal stroke sensor assembly with the 2 nuts.
Firmly depress the brake pedal and break the brake pedal stroke sensor assembly lever set pin.
Remove the broken lever set pin.
When reusing the brake pedal stroke sensor assembly:
Connect the cable to the negative (-) battery terminal.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / ABS/VSC/ TRC / Data List.
![]() |
Reading the value of the brake pedal stroke sensor assembly shown in the Data List, turn the brake pedal stroke sensor assembly slowly to the right and left to adjust the output voltage to the standard voltage.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Stroke Sensor | Stroke sensor / min.: 0 V, max.: 5 V | 0.8 to 1.2 V | - |
Tighten the 2 nuts.
Turn the power switch off.
Disconnect the intelligent tester.
| 5. CHECK AND CLEAR DTC |
Check and clear the DTCs (Click here).
| 6. PERFORM LINEAR VALVE OFFSET LEARNING |
Perform linear valve offset learning (Click here).