LIGHTING SYSTEM > IG Signal Circuit |

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
Read the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| IG SW | Power switch IG signal/ON or OFF | ON: Power switch on (IG) OFF: Power switch off | - |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - BATTERY AND BODY GROUND) |
Disconnect the 2E*1, 2F*2 and 2B instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2E-1*1 - Body ground | Always | 11 to 14 V |
| 2F-1*2 - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2B-6 - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (IG POWER SOURCE CIRCUIT) |
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2B-25 - Body ground | Power switch on (IG) | 11 to 14 V |
| *1 | Front view of wire harness connector (to Instrument Panel Junction Block Assembly) |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
![]() |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Reconnect the instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-32 (IG) - Body ground | Power switch on (IG) | 11 to 14 V |
| *1 | Instrument Panel Junction Block Assembly |
|
| ||||
| OK | ||
| ||