TRIP SWITCH > INSPECTION |
| 1. INSPECT TRIP SWITCH |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (CS) - 12 (E) | Unit change switch pressed | Below 1 Ω |
| 1 (CS) - 12 (E) | Unit change switch not pressed | 10 kΩ or higher |
| 9 (HOUR) - 12 (E) | Hour adjust switch pressed | Below 1 Ω |
| 9 (HOUR) - 12 (E) | Hour adjust switch not pressed | 10 kΩ or higher |
| 10 (MIN) - 12 (E) | Minute adjust switch pressed | Below 1 Ω |
| 10 (MIN) - 12 (E) | Minute adjust switch not pressed | 10 kΩ or higher |
| 11 (RST) - 12 (E) | Set switch pressed | Below 1 Ω |
| 11 (RST) - 12 (E) | Set switch not pressed | 10 kΩ or higher |
Apply battery voltage from the wire harness back side between the terminals of the switch, and check the lighting condition of the trip switch.
| Measurement Condition | Condition | Specified Condition |
| Battery positive (+) → 8 (ILL+) Battery negative (-) → 4 (E) | Always | Trip switch illuminates |
| *1 | Trip Switch (for RHD) |
| *2 | Trip Switch (for LHD) |
| *1 | Component without harness connected (Trip Switch) |