ENGINE IMMOBILISER SYSTEM > Security Indicator Light Does not Blink |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Entry & Start / Active Test.
Perform the Active Test according to the display on the intelligent tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Immobiliser Indicator | Security indicator light | ON or OFF | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT COMBINATION METER ASSEMBLY |
Disconnect the combination meter assembly.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L27-22 (LP) - Body ground |
| Below 2 V |
| L27-22 (LP) - Body ground |
| Pulse generation |
| *1 | Front view of wire harness connector (to Combination Meter Assembly) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BODY GROUND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L27-30 (ES) - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Combination Meter Assembly) |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - COMBINATION METER ASSEMBLY) |
![]() |
Disconnect the certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L62-2 (IND) - L27-22 (LP) | Always | Below 1 Ω |
| L62-2 (IND) - Body ground | Always | 10 kΩ or higher |
| L27-22 (LP) - Body ground | Always | 10 kΩ or higher |
| *1 | Front view of wire harness connector (to Certification ECU (Smart Key ECU Assembly)) |
| *2 | Front view of wire harness connector (to Combination Meter Assembly) |
|
| ||||
| OK | ||
| ||