FRONT DOOR LOCK > INSPECTION |
| 1. INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/o Double Locking System) |
![]() |
Check the operation of the door lock motor.
Apply battery voltage and check the operation of the door lock motor.
| Connection | Result |
| Battery positive (+) → Terminal 4 (L) Battery negative (-) → Terminal 1 (UL) | Locks |
| Battery positive (+) → Terminal 1 (UL) Battery negative (-) → Terminal 4 (L) | Unlocks |
| *1 | Component without harness connected (Front Door Lock Assembly LH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 (E) - 8 (LSSR) | Locked | 10 kΩ or higher |
| 7 (E) - 8 (LSSR) | Unlocked | Below 1 Ω |
| *1 | Component without harness connected (Front Door Lock Assembly LH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door key lock and unlock switch. (for LHD)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 9 (L) - 8 (E) | Locked | Below 1 Ω |
| 9 (L) - 8 (E) | off | 10 kΩ or higher |
| 10 (UL) - 8 (E) | Unlocked | Below 1 Ω |
| 10 (UL) - 8 (E) | off | 10 kΩ or higher |
| *1 | Component without harness connected (Front Door Lock Assembly LH) |
| *2 | Lock |
| *3 | off |
| *4 | Unlock |
| 2. INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/ Double Locking System) |
![]() |
Check the operation of the door lock motor and double lock motor.
Apply battery voltage and check the operation of the door lock motor and double lock motor.
| Connection | Result |
| Battery positive (+) → 4 (L) Battery negative (-) → 3 (UL) | Locks |
| Battery positive (+) → 3 (UL) Battery negative (-) → 4 (L) | Unlocks |
| Battery positive (+) → 2 (DL) Battery negative (-) → 1 (UNDL) | Sets |
| Battery positive (+) → 1 (UNDL) Battery negative (-) → 2 (DL) | Unsets |
| *1 | Component without harness connected (Front Door Lock Assembly LH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door unlock detection switch and double lock position switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 (E) - 8 (LSSR) | Locked | 10 kΩ or higher |
| 7 (E) - 8 (LSSR) | Unlocked | Below 1 Ω |
| 5 (E) - 6 (DLSR) | Unset | 10 kΩ or higher |
| 5 (E) - 6 (DLSR) | Set | Below 1 Ω |
| *1 | Component without harness connected (Front Door Lock Assembly LH) |
| *2 | Unlock |
| *3 | Lock |
| 3. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/o Double Locking System) |
![]() |
Check the operation of the door lock motor.
Apply battery voltage and check the operation of the door lock motor.
| Connection | Result |
| Battery positive (+) → Terminal 4 (L) Battery negative (-) → Terminal 1 (UL) | Locks |
| Battery positive (+) → Terminal 1 (UL) Battery negative (-) → Terminal 4 (L) | Unlocks |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door unlock detection switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 (LSSR) - 8 (E) | Locked | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlocked | Below 1 Ω |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door key lock and unlock switch. (for RHD)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (L) - 8 (E) | Locked | Below 1 Ω |
| 6 (L) - 8 (E) | off | 10 kΩ or higher |
| 5 (UL) - 8 (E) | Unlocked | Below 1 Ω |
| 5 (UL) - 8 (E) | off | 10 kΩ or higher |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Lock |
| *3 | off |
| *4 | Unlock |
| 4. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/ Double Locking System) |
![]() |
Check the operation of the door lock motor and double lock motor.
Apply battery voltage and check the operation of the door lock motor and double lock motor.
| Connection | Result |
| Battery positive (+) → 2 (L) Battery negative (-) → 1 (UL) | Locks |
| Battery positive (+) → 1 (UL) Battery negative (-) → 2 (L) | Unlocks |
| Battery positive (+) → 4 (DL) Battery negative (-) → 3 (UNDL) | Sets |
| Battery positive (+) → 3 (UNDL) Battery negative (-) → 4 (DL) | Unsets |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door unlock detection switch and double lock position switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 (LSSR) - 8 (E) | Locked | 10 kΩ or higher |
| 7 (LSSR) - 8 (E) | Unlocked | Below 1 Ω |
| 9 (DLSR) - 10 (E) | Unset | 10 kΩ or higher |
| 9 (DLSR) - 10 (E) | Set | Below 1 Ω |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Unlock |
| *3 | Lock |
![]() |
Check the operation of the door key lock and unlock switch. (for RHD)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (L) - 8 (E) | Locked | Below 1 Ω |
| 6 (L) - 8 (E) | off | 10 kΩ or higher |
| 5 (UL) - 8 (E) | Unlocked | Below 1 Ω |
| 5 (UL) - 8 (E) | off | 10 kΩ or higher |
| *1 | Component without harness connected (Front Door Lock Assembly RH) |
| *2 | Lock |
| *3 | off |
| *4 | Unlock |