TURN SIGNAL FLASHER ASSEMBLY > INSPECTION |
| 1. INSPECT TURN SIGNAL FLASHER ASSEMBLY |
![]() |
Disconnect the L55 turn signal flasher assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L55-1 (IG) - Body ground | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |
| L55-4 (B) - Body ground | Always | 11 to 14 V |
| *1 | Front view of wire harness connector (to Turn Signal Flasher Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L55-5 (EL) - Body ground | Turn signal switch off | 10 kΩ or higher |
| Turn signal switch in left turn position | Below 1 Ω | |
| L55-6 (ER) - Body ground | Turn signal switch in neutral position | 10 kΩ or higher |
| Turn signal switch in right turn position | Below 1 Ω | |
| L55-7 (E) - Body ground | Always | Below 1 Ω |
| L55-8 (HAZ) - Body ground | Hazard warning switch off | 10 kΩ or higher |
| Hazard warning switch on | Below 1 Ω |
![]() |
Reconnect the L55 turn signal flasher assembly connector.
Measure the voltage according to the valve(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L55-2 (LR) - Body ground | Hazard warning switch off | Below 1 V |
| Hazard warning switch on | 11 to 14 V (60 to 120 times per minute) | |
| Turn signal switch off | Below 1 V | |
| Power switch on (IG) and turn signal switch in RH position | 11 to 14 V (60 to 120 times per minute) | |
| L55-3 (LL) - Body ground | Hazard warning switch off | Below 1 V |
| Hazard warning switch on | 11 to 14 V (60 to 120 times per minute) | |
| Turn signal switch off | Below 1 V | |
| Power switch on (IG) and turn signal switch in LH position | 11 to 14 V (60 to 120 times per minute) |
| *1 | Component with harness connected (Turn Signal Flasher Assembly) |