Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A85-123    Hybrid Battery Pack Cooling Fan 1

for Preparation Click here


DESCRIPTION

Refer to the circuit description for DTC P0A84-123 .

DTC No.
DTC Detection Condition
Trouble Area
P0A85-123
When the output voltage of the battery cooling blower assembly (VM) is too high compared to the target control voltage range (1 trip detection)
  1. Wire harness or connector
  2. Battery cooling blower assembly
  3. Battery smart unit
  4. Hybrid battery thermistor

WIRING DIAGRAM


A216740E02


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After the power switch is turned off, the display and navigation module display (HDD navigation system) records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 60 seconds before disconnecting the cable from the negative (-) battery terminal.

1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Disconnect the intelligent tester from the DLC3.



B
GO TO DTC CHART
A


2.CHECK HARNESS AND CONNECTOR (VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the intelligent tester (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

    NOTICE:
    If the active test cannot be performed, skip it and proceed to the next step to check voltage. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating
    Below 5 V

    Text in Illustration 
    *1
    Component with harness connected
    (Battery Cooling Blower Assembly)

    HINT:
    Measure the voltage on the wire side of the connector that is part of the battery cooling blower assembly.

  1. Turn the power switch off.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



NG
Go to step 5
OK


3.CHECK HYBRID BATTERY THERMISTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



    A217836E01
  1. Disconnect the c1 and z17 connectors from the battery smart unit.



    A216735E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    z17-6 (TB0) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-12 (GB0) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-5 (TB1) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-11 (GB1) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-4 (TB2) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-10 (GB2) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-1 (TC0) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-7 (GC0) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the c1 and z17 connectors to the battery smart unit.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
Go to step 4
OK

REPLACE BATTERY SMART UNIT (Click here)  

4.CHECK HARNESS AND CONNECTOR (INLET AIR TEMPERATURE SENSOR AND BATTERY TEMPERATURE SENSOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Check the wire harness and connectors of the battery temperature sensor and inlet air temperature sensor for abnormalities by sight and touch.

    Specified Condition:
    There are no open or short circuits in the wire harness and connectors. There are no short circuits to other wire harnesses.

  1. Install the upper hybrid battery cover sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR HARNESS OR CONNECTOR
OK

REPLACE HYBRID BATTERY THERMISTOR (Click here)  

5.CHECK HARNESS AND CONNECTOR (VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



    A217834
  1. Disconnect the S14 connector of the battery cooling blower assembly.

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the power switch on (IG).



    A190228E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) - S14-4 (GND0)
    Power switch on (IG)
    Below 5 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)

    NOTICE:
    If the power switch is turned on (IG) with the battery cooling blower assembly connector disconnected, DTC P0A84-123 will be stored. If this DTC is output, clear the DTC using the intelligent tester (Click here).

  1. Connect the S14 connector of the battery cooling blower assembly.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



NG
Go to step 6
OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)  

6.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



    A217834
  1. Disconnect the S14 connector of the battery cooling blower assembly.



    A217836E03
  1. Disconnect the c1 connector of the battery smart unit.



    A217837E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) and c1-7 (VM) - Other terminal
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *2
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the c1 connector of the battery smart unit.

  1. Connect the S14 connector of the battery cooling blower assembly.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BATTERY SMART UNIT (Click here)