DTC P0A85-123 Hybrid Battery Pack Cooling Fan 1 |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0A85-123 | When the output voltage of the battery cooling blower assembly (VM) is too high compared to the target control voltage range (1 trip detection) |
|

| 1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Disconnect the intelligent tester from the DLC3.
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (VOLTAGE) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
Connect the cable to the negative (-) battery terminal.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| S14-2 (VM0) - S14-4 (GND0) | Battery cooling blower is operating | Below 5 V |
| *1 | Component with harness connected (Battery Cooling Blower Assembly) |
Turn the power switch off.
Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
|
| ||||
| OK | |
| 3.CHECK HYBRID BATTERY THERMISTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
![]() |
Disconnect the c1 and z17 connectors from the battery smart unit.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| z17-6 (TB0) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-12 (GB0) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-5 (TB1) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-11 (GB1) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-4 (TB2) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-10 (GB2) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-1 (TC0) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| z17-7 (GC0) - c1-4 (IGCT) | Power switch off | 10 kΩ or higher |
| *1 | Rear view of wire harness connector (to Battery Smart Unit) |
Connect the c1 and z17 connectors to the battery smart unit.
Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
Connect the cable to the negative (-) battery terminal.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (INLET AIR TEMPERATURE SENSOR AND BATTERY TEMPERATURE SENSOR) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the upper hybrid battery cover sub-assembly (Click here).
Check the wire harness and connectors of the battery temperature sensor and inlet air temperature sensor for abnormalities by sight and touch.
Install the upper hybrid battery cover sub-assembly (Click here).
Connect the cable to the negative (-) battery terminal.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (VOLTAGE) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
![]() |
Disconnect the S14 connector of the battery cooling blower assembly.
Connect the cable to the negative (-) battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| S14-2 (VM0) - S14-4 (GND0) | Power switch on (IG) | Below 5 V |
| *1 | Front view of wire harness connector (to Battery Cooling Blower Assembly) |
Connect the S14 connector of the battery cooling blower assembly.
Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
![]() |
Disconnect the S14 connector of the battery cooling blower assembly.
![]() |
Disconnect the c1 connector of the battery smart unit.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| S14-2 (VM0) and c1-7 (VM) - Other terminal | Power switch off | 10 kΩ or higher |
| *1 | Front view of wire harness connector (to Battery Cooling Blower Assembly) |
| *2 | Rear view of wire harness connector (to Battery Smart Unit) |
Connect the c1 connector of the battery smart unit.
Connect the S14 connector of the battery cooling blower assembly.
Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).
Connect the cable to the negative (-) battery terminal.
|
| ||||
| OK | ||
| ||