WIRELESS DOOR LOCK CONTROL SYSTEM > CUSTOMIZE PARAMETERS |
| CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER |
| CUSTOMIZE |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body or Illuminated Entry / Utility / Customize.
Select the setting by referring to the table below.
| Display (item) | Default | Function | Setting |
| Wireless Control | ON | Function that turns wireless door lock function on or off | ON or OFF |
| Hazard Answer Back | ON | When the doors are locked by wireless operation, the hazard warning lights flash once. When the doors are unlocked by wireless operation, the hazard warning lights flash twice. | ON or OFF |
| Open Door Warning | ON | The buzzer sounds when lock is pressed when any of the doors are ajar. | ON or OFF |
| Panic Function*1 | ON | Function to operate theft deterrent system by continuously pressing panic switch on transmitter for 0.8 seconds | ON or OFF |
| Auto Lock Time | 30 s | Function that regulates the interval between unlocking and automatic relocking of doors | 30 s, 60 s or 120 s |
| Wireless Buzzer Resp*2 | ON | Wireless door lock buzzer response | ON or OFF |
| Wireless Buzzer Vol | Level7 | Wireless door lock buzzer volume | Level7, Level6, Level5, Level4, Level3, Level2, Level1 or Level0 |
| Display | Default | Content | Setting |
| Lighting Time | 15 s | Changes the lighting time after closing all doors. (It will quickly fade out in case of turning the power switch from off to on (ACC or IG).) | 7.5 s, 15 s or 30 s |