Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > Pattern Select Switch Power Mode Circuit

for Preparation Click here


DESCRIPTION

When selecting power mode, the switch operation signal is sent to the ECM. Following this, the drive torque is optimally controlled to obtain a sporty feel in response to the driver's acceleration operation.

WIRING DIAGRAM


C190514E01


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (CAN BUS CHECK)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: System Select / CAN Bus Check.

    Result:
    Result
    Proceed to
    All of the ECUs and sensors that are currently connected to the CAN communication system are displayed.
    A
    None of the ECUs and sensors that are currently connected to the CAN communication system are displayed, or some of them are not displayed.
    B



B
GO TO CAN COMMUNICATION SYSTEM (Click here)
A


2.CHECK DTC OUTPUT (ALL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Check for DTCs of all system by following the prompts on the tester screen.
    Result 
    Result
    Proceed to
    No DTCs are output
    A
    DTCs are output
    B



B
GO TO DTC CHART
A


3.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (COMBINATION METER)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. Lamp ECT PWR.

  1. Perform the "Indicat. Lamp ECT PWR" Active Test.

    OK 
    Tester Display
    Description
    Inspection Condition
    Specified Condition
    Indicat. Lamp ECT PWR
    Pattern select indicator light (PWR)
    POWER mode
    Comes on

    Result:
    Result
    Proceed to
    The POWER mode indicator light comes on
    A
    The POWER mode indicator light does not come on
    B



B
REPLACE COMBINATION METER ASSEMBLY (Click here)
A


4.READ VALUE USING INTELLIGENT TESTER (PATTERN SWITCH (PWR/M))
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / Pattern Switch (PWR/M).

  1. Read the value displayed on the intelligent tester.

    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Pattern Switch (PWR/M)
    POWER mode switch condition/
    ON or OFF
    POWER mode switch ON:
    ON
    POWER mode switch OFF:
    OFF
    -

    Result:
    Result
    Proceed to
    The intelligent tester display changes according to the POWER mode switch operation.
    A
    The intelligent tester display does not changes according to the POWER mode switch operation.
    B



B
Go to step 5
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

5.CHECK PATTERN SELECT SWITCH (POWER MODE SWITCH)


    C210637E02
  1. Remove the pattern select switch (POWER mode switch).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L78-7 (PWR) - L78-5 (E)
    POWER Mode Switch ON
    Below 1 Ω
    L78-7 (PWR) - L78-5 (E)
    POWER Mode Switch OFF
    10 kΩ or higher

Text in Illustration 
*1
Pattern Select Switch (POWER Mode Switch)
  1. Install the pattern select switch.



NG
REPLACE PATTERN SELECT SWITCH
OK


6.CHECK HARNESS AND CONNECTOR (POWER MODE SWITCH - BODY GROUND)


    C210638E01
  1. Disconnect connector L78 from the pattern select switch (POWER mode switch).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L78-5 (E) - Body ground
    Always
    Below 1 Ω

Text in Illustration 
*1
Front view of wire harness connector
(to Pattern Select Switch (POWER Mode Switch))
  1. Connect the pattern select switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.CHECK HARNESS AND CONNECTOR (PATTERN SELECT SWITCH (POWER MODE SWITCH) - ECM)
  1. Disconnect connector L78 from the pattern select switch.

  1. Disconnect connector A57 from the ECM.



    C210639E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L78-7 (PWR) - A57-46 (PWMS)
    Always
    Below 1 Ω
    L78-7 (PWR) or A57-46 (PWMS) - Body ground
    Always
    10 kΩ or higher

Text in Illustration 
*1
Front view of wire harness connector
(to Pattern Select Switch (POWER Mode Switch))
*2
Front view of wire harness connector
(to ECM)
  1. Connect the ECM connector.

  1. Connect the pattern select switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)