CAMSHAFT OIL CONTROL VALVE > INSPECTION |
| 1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 6.9 to 7.9 Ω |
Check the operation.
![]() |
Connect a positive (+) battery lead to terminal 1 and a negative (-) lead to terminal 2, and check the movement of the valve.
| *1 | When Applied |
| *2 | When Cut Off |