Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR

AIR CONDITIONING PRESSURE SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL AIR CONDITIONING PRESSURE SENSOR


    E189057
  1. Sufficiently apply compressor oil to a new air conditioning pressure sensor.

    Compressor oil:
    ND-OIL 11 or equivalent

    NOTICE:
    1. Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign objects.
    2. Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the new air conditioning pressure sensor.

    Torque:
    11 N*m{ 110 kgf*cm , 8 ft.*lbf }

    NOTICE:
    1. Do not deform the piping.
    2. Make sure to confirm that the piping does not disengage from the plastic clamp.

  1. Connect the connector.



2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



3. INSTALL REAR NO. 3 FLOOR BOARD


    B227791
  1. Engage the 2 guides to install the rear No. 3 floor board.



4. INSTALL REAR DECK FLOOR BOX
  1. Install the rear deck floor box.



5. INSTALL REAR NO. 2 FLOOR BOARD


    B227788E01
  1. Engage the 3 guides <A>.

  1. Engage the 2 guides <B> and install the rear No. 2 floor board as shown in the illustration.



6. CHARGE WITH REFRIGERANT
  1. Perform vacuum purging using a vacuum pump.



  1. Charge with refrigerant HFC-134a (R134a).


    E143108E05

    Standard:
    470 g (16.6 oz.)

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    NOTICE:
    1. Do not turn the A/C on before charging with refrigerant. Doing so will cause the compressor to work without refrigerant, resulting in overheating of the cooler compressor.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by quantity, not with the sight glass.
    3. Avoid using the gauge manifold set that had been used for vehicles with conventional compressor oil (ND-OIL 8 or equivalent) as much as possible. This will cause compressor oil remaining in the manifold to enter the vehicle, resulting in insulation performance deterioration. A gauge manifold set that had been used 3 times or less can be reused if an appropriate one is not available.

    HINT:
    Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an A/C system.



7. WARM UP COMPRESSOR
  1. Keep the A/C switch on for at least 2 minutes to warm up the compressor.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C on after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



8. INSPECT FOR REFRIGERANT LEAK
  1. After recharging with refrigerant, inspect for refrigerant leaks using a halogen leak detector.

  1. Carry out the test under the following conditions:

    1. Turn the power switch off.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases which are not refrigerant, such as evaporated gasoline and exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that there is some refrigerant remaining in the refrigeration system.
      When the compressor is off: approx. 392 to 588 kPa (3.9 to 5.9 kgf/cm2, 57 to 85 psi)



    I042222E31
  1. Using a halogen leak detector, inspect for refrigerant leaks from the refrigerant lines.
    Text in Illustration 
    *1
    Inspect for Leak
    *2
    Halogen Leak Detector



    N014519E08
  1. Bring the halogen leak detector close to the drain hose with the detector's power off, and then turn the detector on.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *2
    Drain Hose

    HINT:
    1. After the blower motor has stopped, let the cooling unit stand for more than 15 minutes.
    2. Bring the halogen leak detector sensor under the drain hose.
    3. When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to volatile gases. If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow testing.

  1. If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.