Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR

ULTRASONIC SENSOR > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 ULTRASONIC SENSOR


    E181124E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (BI) - 5 (EI)
    Always
    10 kΩ or higher
    1 (BI) - 2 (BO)
    Always
    10 kΩ or higher
    3 (SI) - 4 (SO)
    Always
    Below 1 Ω
    5 (EI) - 6 (EO)
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (No. 1 Ultrasonic Sensor)
    If the result is not as specified, replace the No. 1 ultrasonic sensor.