Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P314A-828    Inverter Coolant Pump Speed Signal

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0C73-776 .
The inverter water pump assembly sends the water pump speed (measured value) signal to the power management control ECU. When the power switch is on (READY), if the water pump speed (measured value) remains too low, this DTC is stored.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P314A
828
When either of the following conditions is met:
  1. A malfunction in the power source circuit or water pump speed signal line of the inverter water pump assembly is detected.
  2. A malfunction in the power source circuit of the inverter water pump assembly or power management control ECU is detected.
  1. Wire harness or connector
  2. Power management control ECU
  3. Inverter water pump assembly
  4. IGCT No. 3 fuse
  5. IGCT relay

Related Data List 
DTC No.
INF Code
Data List Item
P314A
828
  1. Inverter W/P Revolution
  2. W/P Run Control Duty*1
  3. Ready Signal
*1: This Data List item is related to the inverter water pump assembly.

Related Active Test 
DTC No.
INF Code
Active Test
P314A
828
Activate the Water Pump*2
*2: This is an Active Test of the inverter water pump assembly.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0C73-776 .

INSPECTION PROCEDURE

NOTICE:
If DTC P0A78-284, 286, P0A7A-322, 324, P0A94-553 or 557 is output, replace the inverter with converter assembly after this inspection.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 120 seconds or more.

1.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.


NEXT


2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)

NOTICE:
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.

HINT:
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the Activate the Water Pump Active Test.

  1. Touch the inverter water pump assembly and check that it is operating (vibrating).

    OK:
    The water pump is operating (vibrating).

  1. Turn the power switch off.



NG
Go to step 8
OK


3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


  1. Check the connections of the power management control ECU connectors.


    A220952E01


    Text in Illustration 
    *1
    for LHD
    *2
    for RHD

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)


    A232962
  1. Check the connection of the inverter water pump assembly connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


5.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)
  1. Disconnect connector A21 from the power management control ECU.

  1. Disconnect connector g1 from the inverter water pump assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A209031E24


    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *2
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    g1-2 (NWP) - A21-14 (NIWP)
    Power switch off
    Below 1 Ω
    g1-2 (NWP) or A21-14 (NIWP) -Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Connect the power management control ECU connector.

  1. Connect the inverter water pump assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK POWER MANAGEMENT CONTROL ECU
  1. Disconnect connector g1 from the inverter water pump assembly.

  1. Turn the power switch on (IG).



    A204441E36
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A21-14 (NIWP) - L5-6 (E1)
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *1
    Component with harness connected
    (to Power Management Control ECU)

  1. Turn the power switch off.

  1. Connect the inverter water pump assembly connector.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK


7.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.


NEXT


8.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)

NOTICE:
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.

HINT:
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the "Activate the Water Pump" Active Test.



    A281217E04
  1. Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.
    Item
    Content
    Terminal
    A21-14 (NIWP) - L5-6 (E1)
    Equipment Setting
    5 V/DIV., 100 ms./DIV.
    Condition
    Power switch on (IG), during Active Test

    OK:
    The duration of wavelength A is 300 msec or less.

    Text in Illustration 
    *a
    Component with harness connected
    (Power Management Control ECU)

  1. Turn the power switch off.



NG
REPLACE INVERTER WATER PUMP ASSEMBLY (Click here)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

9.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)


    A232962
  1. Check the connection of the inverter water pump assembly connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
Go to step 12
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - IGCT RELAY)
  1. Remove the IGCT relay from the engine room junction block assembly.

  1. Disconnect connector g1 from the inverter water pump assembly.



  1. While slightly shaking the wire harness, connector and engine room relay block and junction block assembly, measure the resistance according to the value(s) in the table below.


    A296742E02


    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    IGCT relay
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 (IGCT relay) - g1-4 (+BWP)
    Power switch off
    Below 1 Ω


    HINT:
    A288054E02
    1. Connectors
      1. Slightly shake the connector vertically and horizontally.
    2. Wire Harness
      1. Slightly shake the wire harness vertically and horizontally.
      2. The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
    3. Engine Room Relay Block and Junction Block Assembly
      1. Apply slight vibration with a finger to the engine room relay block and junction block assembly and check whether a malfunction occurs.
    Text in Illustration 
    *a
    Example
    *b
    Shake Slightly
    *c
    Vibrate Slightly

    NOTICE:
    Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.

  1. Connect the inverter water pump assembly connector.

  1. Install the IGCT relay.



NG
Go to step 13
OK


11.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
  1. Disconnect connector g1 from the inverter water pump assembly.



    A288050E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    g1-1 (GND) - Body ground
    Power switch on (IG)
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Water Pump with Motor Assembly)

  1. Connect the inverter water pump assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE INVERTER WATER PUMP ASSEMBLY (Click here)  

12.CHECK FUSE (IGCT NO. 3)


    A216748E01
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT No. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT No. 3 Fuse

  1. Install the IGCT No. 3 fuse.



NG
Go to step 23
OK

CONNECT SECURELY (INVERTER WATER PUMP ASSEMBLY CONNECTOR)) 

13.CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE)
  1. Check installation condition of the IGCT No. 3 fuse.

OK:
IGCT No. 3 fuse is installed correctly.



NG
Go to step 16
OK


14.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Remove the IGCT relay from the engine room relay block and junction block assembly.

  1. Disconnect connector g1 from the inverter water pump assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A296744E01


    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    IGCT No. 3 Fuse
    *3
    IGCT Relay
    -
    -
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    2 (IGCT No. 3 fuse) - g1-4 (+BWP)
    Power switch off
    Below 1 Ω
    1 (IGCT No. 3 fuse) - 5 (IGCT relay)
    Power switch off
    Below 1 Ω
    2 (IGCT No. 3 fuse) or g1-4 (+BWP) - Body ground and other terminals
    Power switch off
    10kΩ or higher

    NOTICE:
    Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.

  1. Connect the inverter water pump assembly connector.

  1. Install the IGCT relay.

  1. Install the IGCT No. 3 fuse.



NG
Go to step 18
OK


15.CHECK FUSE (IGCT NO. 3)


    A216748E01
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT No. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT No. 3 Fuse



NG
Go to step 19
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

16.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
  1. Check the terminals of the IGCT No. 3 fuse holder.

    OK:
    The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded.



NG
Go to step 22
OK


17.CHECK FUSE (IGCT NO. 3)


    A216748E01
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT No. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT No. 3 Fuse



NG
REPLACE FUSE (IGCT NO. 3)
OK

CONNECT SECURELY (IGCT NO. 3 FUSE) 

18.CHECK FUSE (IGCT NO. 3)


    A216748E01
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT No. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT No. 3 Fuse



NG
Go to step 24
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

19.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
  1. Disconnect connector g1 from the inverter water pump assembly.



    A288050E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    g1-1 (GND) - Body ground
    Power switch on (IG)
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Water Pump with Motor Assembly)

  1. Connect the inverter water pump assembly connector.



NG
Go to step 24
OK


20.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
  1. Check the terminals of the IGCT No. 3 fuse holder.

    OK:
    The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded.



NG
Go to step 25
OK


21.REPLACE INVERTER WATER PUMP ASSEMBLY
  1. Replace the inverter water pump assembly (Click here).


NEXT

REPLACE FUSE (IGCT NO. 3) 

22.CHECK FUSE (IGCT NO. 3)


    A216748E01
  1. Remove the IGCT No. 3 fuse from the engine room junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT No. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT No. 3 Fuse



NG
Go to step 25
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

23.CONNECT SECURELY

NEXT

REPLACE FUSE (IGCT NO. 3) 

24.REPAIR OR REPLACE HARNESS AND CONNECTOR

NEXT

REPLACE FUSE (IGCT NO. 3) 

25.REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINAL)

NEXT