LUMBAR SWITCH (for Manual Seat) > INSPECTION |
| 1. INSPECT LUMBAR SWITCH (for LHD) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 2 | Hold | Below 1 Ω |
| 1 - 2 | Off | Below 1 Ω |
| 1 - 2 | Release | 10 kΩ or higher |
| 3 - 4 | Hold | Below 1 Ω |
| 3 - 4 | Release | 10 kΩ or higher |
| 5 - 4 | Hold | 10 kΩ or higher |
| 5 - 4 | Off | Below 1 Ω |
| 5 - 4 | Release | Below 1 Ω |
| 1 - 3 | Hold | 10 kΩ or higher |
| 1 - 3 | Release | Below 1 Ω |
| *1 | Hold |
| *2 | Release |
| *3 | Component without harness connected (Lumbar Switch LH) |
| 2. INSPECT LUMBAR SWITCH (for RHD) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 2 | Hold | Below 1 Ω |
| 1 - 2 | Off | Below 1 Ω |
| 1 - 2 | Release | 10 kΩ or higher |
| 3 - 4 | Hold | Below 1 Ω |
| 3 - 4 | Release | 10 kΩ or higher |
| 5 - 4 | Hold | 10 kΩ or higher |
| 5 - 4 | Off | Below 1 Ω |
| 5 - 4 | Release | Below 1 Ω |
| 1 - 3 | Hold | 10 kΩ or higher |
| 1 - 3 | Release | Below 1 Ω |
| *1 | Hold |
| *2 | Release |
| *3 | Component without harness connected (Lumbar Switch RH) |