Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL

HYBRID / BATTERY CONTROL > SERVICE DATA



Reserve Tank Cap (for Inverter) 
Item
Specified Condition
Standard value (for brand-new cap)
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi)
Minimum standard value (for used cap)
94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay 
Item
Tester Connection
Specified Condition
No. 1 circuit breaker sensor
1 (SIF-) - 2 (SIF+)
0.65 to 1.0 kΩ at 20°C (68°F)
IGCT relay
Resistance
3 - 5
10 kΩ or higher
(When battery voltage is not applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(When battery voltage is applied between terminals 1 and 2)

Hybrid Battery Junction Block 
SMRB
Resistance
4 (SMRB) - 2 (GND)
19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))
SMRG
Resistance
1 (SMRG) - 2 (GND)
19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))
SMRP
Resistance
3 (SMRP) - 2 (GND)
112 to 274 Ω (at -40°C (-40°F) to 80°C (176°F))
Precharge
resistor
-
28.5 to 31.5 Ω
Electric vehicle fuse
-
Below 1 Ω

Service plug grip 
Service plug grip
-
Below 1 Ω