BLOCKING SYSTEM > TERMINALS OF ECU |
| CHECK TELEPHONE TRANSCEIVER ASSEMBLY |
Disconnect the L156 telephone transceiver assembly connector.

Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L156-6 (IG2) - L156-9 (E) | L - BR | Ignition power supply | Power switch on (IG) | 9 to 16 V |
| L156-12 (+B) - L156-9 (E) | SB - BR | +B power supply | Power switch off | 9 to 16 V |
| L156-9 (E) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
Reconnect the L156 telephone transceiver assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L156-1 (BLK1) - L156-9 (E) | L - BR | ID code box (immobiliser code ECU) communication input | Power switch off | 11 to 14 V |
| L156-1 (BLK1) - L156-9 (E) | L - BR | ID code box (immobiliser code ECU) communication input | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected | Pulse generation (See waveform 1) |
| L156-2 (BLK4) - L156-9 (E) | R - BR | ID code box (immobiliser code ECU) communication output | Power switch off | Below 1 V |
| L156-2 (BLK4) - L156-9 (E) | R - BR | ID code box (immobiliser code ECU) communication output | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected | Pulse generation (See waveform 2) |
| L156-7 (BLK2) - L156-9 (E) | L -BR | Power management control ECU (HV CPU) communication output | Power switch off | Below 1 V |
| L156-7 (BLK2) - L156-9 (E) | L - BR | Power management control ECU (HV CPU) communication output | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected | Pulse generation (See waveform 1) |
| L156-8 (BLK3) - L156-9 (E) | R - BR | Power management control ECU (HV CPU) communication input | Power switch off | Below 1 V |
| L156-8 (BLK3) - L156-9 (E) | R - BR | Power management control ECU (HV CPU) communication input | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected | Pulse generation (See waveform 2) |
Inspect using an oscilloscope.
Waveform 1 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection |
|
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected |
Waveform 2 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection |
|
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Within 3 seconds of power switch on (READY), or within 3 seconds of power switch turned on (IG) after auxiliary battery cable disconnected and reconnected |
| CHECK ID CODE BOX (IMMOBILISER CODE ECU) |
Disconnect the L10 ID code box (immobiliser code ECU) connector.

Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L10-1 (+B) - L10-8 (GND) | B - W-B | +B power supply | Power switch off | 11 to 14 V |
| L10-8 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the L10 ID code box (immobiliser code ECU) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L10-5 (EFII) - L10-8 (GND) | L - W-B | Power management control ECU (HV CPU) input signal | Power switch off | 11 to 14 V |
| L10-5 (EFII) - L10-8 (GND) | L - W-B | Power management control ECU (HV CPU) input signal | Within 3 seconds after power switch on (READY), or within 3 seconds after power switch first turned on (IG) after auxiliary battery disconnected and connected | Pulse generation (See waveform 1) |
| L10-6 (EFIO) - L10-8 (GND) | R - W-B | Power management control ECU (HV CPU) output signal | Power switch off | Below 1 V |
| L10-6 (EFIO) - L10-8 (GND) | R - W-B | Power management control ECU (HV CPU) output signal | Power switch on (IG) | Pulse generation (See waveform 2) |
Inspect using an oscilloscope.
Waveform 1 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection | L10-5 (EFII) - L10-8 (GND) |
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Within 3 seconds after power switch on (READY), or within 3 seconds after power switch first turned on (IG) after auxiliary battery disconnected and connected |
Waveform 2 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection | L10-6 (EFIO) - L10-8 (GND) |
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Power switch on (IG) |
| CHECK POWER MANAGEMENT CONTROL ECU (HV CPU) |
Disconnect the L5 power management control ECU (HV CPU) connector.

Measure the resistance according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L5-6 (E1) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
Reconnect the L5 power management control ECU (HV CPU) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| L6-20 (IMO) - L5-6 (E1) | L - BR | ID code box (immobiliser code ECU) input signal | Power switch off | 11 to 14 V |
| L6-20 (IMO) - L5-6 (E1) | L - BR | ID code box (immobiliser code ECU) input signal | Within 3 seconds after power switch on (READY), or within 3 seconds after power switch first turned on (IG) after auxiliary battery disconnected and connected | Pulse generation (See waveform 1) |
| L6-21 (IMI) - L5-6 (E1) | R - BR | ID code box (immobiliser code ECU) output signal | Power switch off | Below 1 V |
| L6-21 (IMI) - L5-6 (E1) | R - BR | ID code box (immobiliser code ECU) output signal | Power switch on (IG) | Pulse generation (See waveform 2) |
Waveform:
Waveform 1 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection | L6-20 (IMO) - L5-6 (E1) |
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Within 3 seconds after power switch on (READY), or within 3 seconds after power switch first turned on (IG) after auxiliary battery disconnected and connected |
Waveform 2 (Reference)

| *a | Approximately 160 ms | *b | Approximately 510 ms |
| Item | Content |
| Tester Connection | L6-21 (IMI) - L5-6 (E1) |
| Tool Setting | 2 V/DIV., 500 ms./DIV. |
| Condition | Power switch on (IG) |