COOLING SYSTEM > DETAILS



CONSTRUCTION


  1. Water Pump Assembly



    1. An electric water pump, which operates in response to ECM signals, regulates the coolant flow volume, thus, the warm-up performance is further enhanced as well as reducing the cooling loss.


      W101572E01


      Text in Illustration 
      *1
      Timing Chain Cover Assembly
      *2
      Water Pump Assembly
      *3
      1. Water Inlet Housing Assembly
        1. Thermostat
      *4
      Stator
      *5
      Impeller
      *6
      Shaft
      *7
      Cross Section
      -
      -



  2. Cooling Fan



    1. A ring type cooling fan is used. In addition, swirl generation is reduced by enlarging the fan feather edges and thus fan noise has been reduced and cooling ability has been optimized.


      W101573E01


      Text in Illustration 
      *1
      Radiator Assembly
      *2
      Cooling Fan Motor
      *3
      Cooling Fan
      *4
      '09 Prius
      *5
      Conventional Models
      -
      -