SFI SYSTEM > PRECAUTION |
| 1.INITIALIZATION |
| 2.PRECAUTIONS FOR INSPECTING HYBRID CONTROL SYSTEM |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
![]() |
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.
| 3.NOTICE FOR HYBRID CONTROL SYSTEM ACTIVATION |
When the warning light is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the power switch on (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the power switch off and reattempt to start the hybrid system.
| 4.FOR USING TECHSTREAM |
| 5.DISCONNECTING AND RECONNECTING NEGATIVE AUXILIARY BATTERY CABLE |
![]() |
Before performing work on electronic components, disconnect the cable from the negative (-) auxiliary battery terminal to prevent damage to the electrical system or electrical components.
| *1 | Negative (-) Auxiliary Battery Terminal |
| *2 | Cable |
Before disconnecting and reconnecting the auxiliary battery cable, turn the power switch off and the headlight switch off. Then loosen the terminal nut completely. Do not damage the cable or terminal.
When the auxiliary battery cable is disconnected, the clock and radio settings and stored DTCs are cleared. Therefore, before disconnecting the auxiliary battery cable, make a note of them.