SLIDING ROOF SYSTEM > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Sliding Roof / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Open Switch | OPEN switch signal/ON or OFF | ON: OPEN switch pressed OFF: OPEN switch not pressed | - |
| Close Switch | CLOSE switch signal/ON or OFF | ON: CLOSE switch pressed OFF: CLOSE switch not pressed | - |
| Hall IC1 Pulse | Hall IC1 pulse output/Lo or Hi | Lo and Hi repeat during motor operation | Lo: Hall IC1 output is low Hi: Hall IC1 output is high |
| Hall IC1 Status | Status of Hall IC1/Normal or Error | Normal: Hall IC1 is normal Error: Hall IC1 is not normal | - |
| Hall IC2 Pulse | Hall IC2 pulse output/Lo or Hi | Lo and Hi repeat during motor operation | Lo: Hall IC2 output is low Hi: Hall IC2 output is high |
| Hall IC2 Status | Status of Hall IC2/Normal or Error | Normal: Hall IC2 is normal Error: Hall IC2 is not normal | - |
| Ignition (Direct Signal) | Power switch signal/ON or OFF | ON: Power switch on (IG) OFF: Power switch off | - |
| Ignition (MPX) | Power switch signal (LIN signal)/ON or OFF | ON: Power switch on (IG) OFF: Power switch off | - |
| Door Courtesy | Driver side door courtesy light switch signal/ON or OFF | ON: Driver side door open OFF: Driver side door closed | - |
| Key Off Permission | Key-off sliding roof operation permit signal/ON or OFF | ON: Front doors are not opened within 45 seconds after power switch turned off OFF: Any status except "ON" status | - |
| Open Switch Failure(Past) | Open switch failure signal (Past)/ON or OFF | ON: Sliding roof open signal failure (Past) OFF: Sliding roof open signal not fail (Past) | - |
| Close Switch Failure(Past) | Close switch failure signal (Past)/ON or OFF | ON: Sliding roof close signal failure (Past) OFF: Sliding roof close signal not fail (Past) | - |
| Open Switch Failure(Current) | Open switch failure signal (Current)/ON or OFF | ON: Sliding roof open signal failure (Current) OFF: Sliding roof open signal not fail (Current) | - |
| Close Switch Failure(Current) | Close switch failure signal (Current)/ON or OFF | ON: Sliding roof close signal failure (Current) OFF: Sliding roof close signal not fail (Current) | - |
| PERFORM ACTIVE TEST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Sliding Roof / Active Test.
Perform the Active Test according to the display on the Techstream.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Slide Roof | Operate sliding roof | Opn/Dwn / Clos/Up / OFF | - |