CAN COMMUNICATION SYSTEM > Yaw Rate Sensor Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| Yaw Rate Sensor Communication Stop Mode |
|
|

| 1.CHECK CAN BUS WIRE FOR DISCONNECTION (YAW RATE SENSOR BRANCH WIRE) |
Turn the power switch off.
![]() |
Disconnect the yaw rate sensor connector.
| *1 | Front view of wire harness connector (to Yaw Rate Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L12-3 (CANH) - L12-2 (CANL) | Power switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL) |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L12-4 (IG) - Body ground | Power switch on (IG) | 11 to 14 V |
| *1 | Front view of wire harness connector (to Yaw Rate Sensor) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (GROUND TERMINAL) |
Turn the power switch off.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L12-1 (GND) - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Yaw Rate Sensor) |
|
| ||||
| OK | ||
| ||