DTC P3233-750 Open or Short to B+ in Blocking of HV Gate Connection |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3233 | 750 | Open or short to +B in the emergency shutdown signal line (HSDN) when the IGBTs are operating. (1 trip detection logic) |
|
| DTC No. | Data List |
| P3233-750 |
|
| 1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector A59 from the inverter with converter assembly.
Disconnect connector A22 from the power management control ECU.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A22-31 (HSDN) - Body ground | Power switch off | Below 1 V |
| *1 | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *2 | Rear view of wire harness connector (to Power Management Control ECU) |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A22-31 (HSDN) - A59-31 (HSDN) | Power switch on (IG) | Below 1 Ω |
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
|
| ||||
| OK | |
| 2.CHECK INVERTER WITH CONVERTER ASSEMBLY |
Check that the service plug grip is not installed.
Disconnect connector A59 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A59-31 (HSDN) - A59-10 (+B) | Power switch off | 80 Ω or higher |
| A59-31 (HSDN) - A59-9 (+B2) | Power switch off | 80 Ω or higher |
| A59-31 (HSDN) - A59-28 (GND1) | Power switch off | 2.65 to 3.55 kΩ |
| *1 | Component without harness connected (Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||