Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A1B-168    Drive Motor "A" Control Module

DTC    P0A1B-795    Drive Motor "A" Control Module

DTC    P0A1B-796    Drive Motor "A" Control Module

for Preparation Click here


DESCRIPTION

The inverter with converter assembly (MG ECU) monitors its internal operation and detects malfunctions.

HINT:
The term "drive motor A" indicates motor (MG2).


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A1B
168
Motor resolver angle error
The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit.
(1 trip detection logic)
  1. Inverter with converter assembly
  2. Hybrid vehicle transaxle assembly
  3. Wire harness or connector
795
Resolver REF signal cycle error
Excitation signal (REF signal) for resolver angle detection cycle error
(1 trip detection logic)
796
Resolver REF signal oscillation stop error
An error is detected when the excitation signal (REF signal) for resolver angle detection is not detected.
(1 trip detection logic)

Related Data List 
DTC No.
Data List
P0A1B-168
Motor (MG2) Revolution
P0A1B-795
P0A1B-796

MONITOR DESCRIPTION

The MG ECU (in the inverter with converter assembly) performs many diagnostic tests to verify proper operation of internal ECU systems. In one of those tests, the MG ECU checks for an R/D (Resolver/ Digital converter) malfunction involving the motor resolver. If the MG ECU detects an R/D converter error, it will conclude that there is an internal malfunction involving the motor resolver. The power management control ECU (HV CPU) will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A1B (INF 168): R/D converter resolver angle abnormality
P0A1B (INF 795): REF malfunction (frequency abnormality)
P0A1B (INF 796): REF malfunction (REF Signal abnormality)
Required sensors / components
Inverter with converter (MG ECU)
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU (HV CPU)
DTC P0A1B (INF 168/795/796) is not detected

CONFIRMATION DRIVING PATTERN


A308311E06

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 30 seconds or more.
  5. Turn the power switch on (IG) and wait for 5 seconds or more.
  6. Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more. [A]
  7. Drive the vehicle at 3 mph (5 km/h) or more for 5 seconds or more. [B]
  8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  9. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  10. Check that permanent DTCs are cleared.
  11. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
  1. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Turn the power switch on (IG) and wait for 5 seconds or more.
    2. Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.
    3. Drive the vehicle at 3 mph (5 km/h) or more for 5 seconds or more.
  2. When a resolver signal error exists, the vehicle may not drive smoothly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A1B-168 , 795 or 796 only is output or DTCs except the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit

  1. Turn the power switch off.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY)
A214648

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

  1. Check the connection of the low voltage connector of the inverter with converter assembly.

    OK:
    The connector is connected securely and there are no contact problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-12 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-7 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-8 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-10 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-9 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the low voltage connector from the inverter with converter assembly.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK GENERATOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - D29-12 (GRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-7 (GSN) - D29-8 (GSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-10 (GCS) - D29-9 (GCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 9
OK


5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-2 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-3 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-4 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-6 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-5 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK MOTOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - D29-2 (MRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-3 (MSN) - D29-4 (MSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-6 (MCS) - D29-5 (MCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 11
OK


7.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


8.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

9.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217748E01
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) - D29-11 (GRF)
    Power switch off
    Below 1 Ω
    D7-5 (GRFG) - D29-12 (GRFG)
    Power switch off
    Below 1 Ω
    D7-2 (GSN) - D29-7 (GSN)
    Power switch off
    Below 1 Ω
    D7-6 (GSNG) - D29-8 (GSNG)
    Power switch off
    Below 1 Ω
    D7-3 (GCS) - D29-10 (GCS)
    Power switch off
    Below 1 Ω
    D7-7 (GCSG) - D29-9 (GCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) or D29-11 (GRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-5 (GRFG) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-2 (GSN) or D29-7 (GSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-6 (GSNG) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-3 (GCS) or D29-10 (GCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-7 (GCSG) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Generator Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

11.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


12.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217749E01
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) - D29-1 (MRF)
    Power switch off
    Below 1 Ω
    D1-6 (MRFG) - D29-2 (MRFG)
    Power switch off
    Below 1 Ω
    D1-1 (MSN) - D29-3 (MSN)
    Power switch off
    Below 1 Ω
    D1-4 (MSNG) - D29-4 (MSNG)
    Power switch off
    Below 1 Ω
    D1-2 (MCS) - D29-6 (MCS)
    Power switch off
    Below 1 Ω
    D1-5 (MCSG) - D29-5 (MCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) or D29-1 (MRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-6 (MRFG) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-1 (MSN) or D29-3 (MSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-4 (MSNG) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-2 (MCS) or D29-6 (MCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-5 (MCSG) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Motor Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)