DTC P0A37-260 Generator Temperature Sensor Circuit Range / Performance |
DTC P0A3A-258 Generator Temperature Sensor Circuit Intermittent |

| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A37 | 260 | Generator temperature sensor output does not increase in which the value should increase, or output does not decrease under conditions in which the value should decrease. (1 trip detection logic) | Hybrid vehicle generator assembly (Generator temperature sensor) |
| P0A3A | 258 | Sudden change in generator temperature sensor output or hunting Unusual sudden change in generator temperature sensor output occurs and offset condition continues for a certain period of time, or unusual change in motor temperature sensor output occurs repeatedly. (1 trip detection logic) |
| DTC No. | Data List |
| P0A37-260 | Motor Temp No2 |
| P0A3A-258 |
| 1.REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY |
Replace the hybrid vehicle generator assembly (Click here).
| NEXT | ||
| ||