DTC P0A7A-344 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 344 | Generator (MG1) torque execution monitoring malfunction The difference between the generator torque requested by the power management ECU and actual motor torque is large. (1 trip detection logic) |
|
| DTC No. | Data List |
| P0A7A-344 |
|
| Related DTCs | P0A7A (INF 344): Discrepancy between generator monitored torque and commanded torque |
| Required sensors / components | Generator inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU (HV CPU) | DTC P07A (INF 344) is not detected |

| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-344 only is output or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-203, 325, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC/DC Converter Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-132 | High Voltage Power Resource |
| P3233-750 | Open or Short to B+ in Blocking of HV Gate Connection |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
![]() |
Check that the service plug grip is not installed.
Check the connection of the low voltage connector of the inverter with converter assembly.
|
| ||||
| OK | |
| 3.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the bolts for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 4.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
![]() |
Check generator for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| f1-1 (W) - f1-2 (U) | Power switch off | 89.5 to 98.9mΩ |
| f1-2 (U) - f1-3 (V) | Power switch off | 89.5 to 98.9mΩ |
| f1-3 (V) - f1-1 (W) | Power switch off | 89.5 to 98.9mΩ |
| *1 | Generator Cable |
| *2 | Shield Ground |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| f1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the inverter terminal cover.
|
| ||||
| OK | ||
| ||
| 5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the inverter with converter assembly.
![]() |
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Disconnect the generator cable from the hybrid vehicle transaxle assembly.
Check for arc marks at the bolts for the generator cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
|
| ||||
|
| ||||
| A | |
| 6.CHECK GENERATOR CABLE |
Check that the service plug grip is not installed.
Remove the generator cable.
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| f1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Generator Cable (Inverter with Converter Assembly Side) |
| *2 | Shield ground |
| *3 | Generator Cable (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| f1-1 (W) - f2-3 (W) | Power switch off | Below 1 Ω |
| f1-2 (U) - f2-2 (U) | Power switch off | Below 1 Ω |
| f1-3 (V) - f2-1 (V) | Power switch off | Below 1 Ω |
| f1-1 (W) - f2-2 (U) | Power switch off | 100 MΩ or higher |
| f1-2 (U) - f2-1 (V) | Power switch off | 100 MΩ or higher |
| f1-3 (V) - f2-3 (W) | Power switch off | 100 MΩ or higher |
Install the generator cable.
|
| ||||
| OK | ||
| ||