Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › OCCUPANT CLASSIFICATION SYSTEM

OCCUPANT CLASSIFICATION SYSTEM > TERMINALS OF ECU

for Preparation Click here



OCCUPANT CLASSIFICATION ECU

H100909E26


Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specification
W3-1 (+B) - W3-3 (GND)
W - W-B
Auxiliary battery
Always
11 to 14 V
W3-2 (DIA) - W3-3 (GND)
GR - W-B
Diagnosis (DLC3)
Power switch on (IG)
Pulse generation
W3-3 (GND) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
W3-4 (FSR-) - W3-3 (GND)
LG - W-B
Center airbag sensor assembly communication line
Always
Below 1 V
W3-5 (BGND) - W3-3 (GND)
P - W-B
Passenger side buckle switch ground line
Always
Below 1 V
W3-7 (IG) - W3-3 (GND)
B - W-B
Power source
Power switch on (IG)
11 to 14 V
W3-8 (FSR+) - W3-4 (FSR-)
L - LG
Center airbag sensor assembly communication line
Power switch on (IG)
Pulse generation
W3-9 (BSW) - W3-5 (BGND)
G - P
Passenger side buckle switch line
Always
Pulse generation
W2-1 (SGD1) - W3-3 (GND)
G - W-B
Front occupant classification sensor LH ground line
Always
Below 1 V
W2-2 (SGD2) - W3-3 (GND)
LG - W-B
Front occupant classification sensor RH ground line
Always
Below 1 V
W2-3 (SGD3) - W3-3 (GND)
W - W-B
Rear occupant classification sensor LH ground line
Always
Below 1 V
W2-4 (SGD4) - W3-3 (GND)
BR - W-B
Rear occupant classification sensor RH ground line
Always
Below 1 V
W2-5 (SVC3) - W2-3 (SGD3)
GR - W
Rear occupant classification sensor LH power supply line
Power switch on (IG)
4.9 to 5.1 V
W2-6 (SVC4) - W2-4 (SGD4)
V - BR
Rear occupant classification sensor RH power supply line
Power switch on (IG)
4.9 to 5.1 V
W2-7 (SIG1) - W2-1 (SGD1)
P - G
Front occupant classification sensor LH signal line
Power switch on (IG), a load applied to front occupant classification sensor LH
0 to 5.1 V
W2-8 (SIG2) - W2-2 (SGD2)
L - LG
Front occupant classification sensor RH signal line
Power switch on (IG), a load applied to front occupant classification sensor RH
0 to 5.1 V
W2-9 (SIG3) - W2-3 (SGD3)
SB - W
Rear occupant classification sensor LH signal line
Power switch on (IG), a load applied to rear occupant classification sensor LH
0 to 5.1 V
W2-10 (SIG4) - W2-4 (SGD4)
B - BR
Rear occupant classification sensor RH signal line
Power switch on (IG), a load applied to rear occupant classification sensor RH
0 to 5.1 V
W2-11 (SVC1) - W2-1 (SGD1)
R - G
Front occupant classification sensor LH power supply line
Power switch on (IG)
4.9 to 5.1 V
W2-12 (SVC2) - W2-2 (SGD2)
W - LG
Front occupant classification sensor RH power supply line
Power switch on (IG)
4.9 to 5.1 V