OCCUPANT CLASSIFICATION SYSTEM > INITIALIZATION |
| ZERO POINT CALIBRATION |
Zero point calibration procedure
Check that all of the following conditions are met:
Adjust the seat position according to the table below.
| Adjustment Item | Position |
| Slide Direction | Rearmost position |
| Reclining Angle | Upright position |
| Headrest Height | Lowest position |
| Lifter Height | Lowest position |
Turn the power switch off.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration.
Perform zero point calibration by following the prompts on the Techstream screen.
| SENSITIVITY CHECK |
Sensitivity check procedure
Turn the power switch off.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Occupant Detection / Utility / Sensitivity Check.
Perform sensitivity check by following the prompts on the Techstream screen.
Confirm that the initial sensor reading is within the specified range.
Place a 30 kg (66.1 lb) weight (e.g. a 30 kg (66.1 lb) of lead mass) onto the front passenger seat.
Confirm that sensitivity is within the specified range.