Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness

for Preparation Click here


DESCRIPTION

The meter ECU (No. 3 meter circuit plate) receives signals from this circuit to adjust the illumination of the meter, and instrument panel. The meter ECU (No. 3 meter circuit plate) sets the illumination level based on the user operation of the light control rheostat.

HINT:
  1. The meter illumination level can be adjusted by operating the light control rheostat.
  1. The meter illumination dims when the light control switch is turned to the tail or head position at night.
  1. Setting the meter illumination to maximum brightness cancels the above dimming of the meter illumination.
  1. Setting the meter illumination to minimum brightness turns off the meter illumination when the light control switch is changed to the tail or head position.


WIRING DIAGRAM


E163225E05


INSPECTION PROCEDURE

1.SYSTEM CHECK
  1. Confirm the symptoms.


Result:

Result
Proceed to
Meter illumination does not change in operating the light control rheostat.
A
Dimmer function cannot be canceled.
B



B
Go to step 6
A


2.READ VALUE USING TECHSTREAM (RHEOSTAT VALUE)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Rheostat value
    Light control rheostat/Min.: 0 (dark), Max.: 255 (bright)
    The light control rheostat value 0 (dark)
    The value changes with the rheostat operation
    The light control rheostat value 255 (bright)

    OK:
    The value displayed on the Techstream gradually changes as the actual rheostat knob operation.



NG
Go to step 4
OK


3.READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tail Cancel SW
    Tail cancel switch/OFF or ON
    OFF: Tail cancel switch off
    -
    ON: Tail cancel switch on
    -

    HINT:
    The tail cancel switch is operated by turning the light control rheostat knob fully upward

    OK:
    Condition displayed on the Techstream is the same as the actual light control rheostat knob position.



NG
Go to step 7
OK

REPLACE COMBINATION METER ASSEMBLY (NO. 3 METER CIRCUIT PLATE) (Click here)  

4.INSPECT LIGHT CONTROL RHEOSTAT


    E184972E01
  1. Remove the light control rheostat.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 (E) - 3 (TR)
    Turn the light control rheostat knob fully downwards (MIN.)
    Below 50 Ω
    Light control rheostat knob position is between MIN. and MAX.
    The value changes gradually (Between 0 to 12 kΩ)
    Turn the light control rheostat knob fully upwards (MAX.)
    8 to 12 kΩ

    Text in Illustration 
    *1
    Component without harness connected
    (Light Control Rheostat)



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - LIGHT CONTROL RHEOSTAT)
  1. Disconnect the L27 and L59 connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L27-37 (SW2) - L59-3 (TR)
    Always
    Below 1 Ω
    L27-37 (SW2) - Body ground
    Always
    10 kΩ or higher
    L27-38 (SW3) - L59-1 (E)
    Always
    Below 1 Ω
    L27-38 (SW3) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (NO. 3 METER CIRCUIT PLATE) (Click here)  

6.READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tail Cancel SW
    Tail cancel switch/OFF or ON
    OFF: Tail cancel switch off
    -
    ON: Tail cancel switch on
    -

    HINT:
    The tail cancel switch is operated by turning the light control rheostat knob fully upward

    OK:
    Condition displayed on the Techstream is the same as the actual light control rheostat knob position.



NG
Go to step 7
OK


7.INSPECT LIGHT CONTROL RHEOSTAT


    E184972E02
  1. Remove the light control rheostat.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 (TC) - 7 (T)
    Light control rheostat position is except below
    Below 50 Ω
    Turn the light control rheostat knob fully upwards (Tail cancel switch is on)
    8 to 12 kΩ

    Text in Illustration 
    *1
    Component without harness connected
    (Light Control Rheostat)



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK


8.CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - LIGHT CONTROL RHEOSTAT)
  1. Disconnect the L27 and L59 connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L27-36 (SW1) - L59-7 (T)
    Always
    Below 1 Ω
    L27-36 (SW1) - Body ground
    Always
    10 kΩ or higher
    L27-35 (TC) - L59-5 (TC)
    Always
    Below 1 Ω
    L27-35 (TC) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (NO. 3 METER CIRCUIT PLATE) (Click here)