AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) | Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) | - | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) | Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Solar sensor / Min.: 0 Max.: 255 | Solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Set temperature / Min.: MAX COLD Max.: MAX HOT | Actual set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -66.22 psi (gauge) Max.: 477.68 psi (gauge) | Actual regulator pressure displayed | - |
| Air Mix Servo Targ Pulse(D) | Air mix servo motor target pulse / Min.: 0 Max.: 255 | MAX. COLD: 6 (pulse) MAX. HOT: 93 (pulse) | - |
| Air Mix Servo Actual Pulse(D) | Air mix servo motor actual pulse / Min.: 0 Max.: 255 | MAX. COLD: 6 (pulse) MAX. HOT: 93 (pulse) | - |
| Air Outlet Servo Pulse (D) | Air outlet servo motor target pulse / Min.: 0 Max.: 255 | FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 17(pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) | - |
| Air Outlet Servo Actu Pulse(D) | Air outlet servo motor actual pulse / Min.: 0 Max.: 255 | FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 17 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) | - |
| Air Inlet Damper Targ Pulse | Air inlet servo motor target pulse / Min.: 0 Max.: 255 | RECIRCULATION: 19 (pulse) FRESH: 7 (pulse) | - |
| Air Inlet Damper Actual Pulse | Air inlet servo motor actual pulse / Min.: 0 Max.: 255 | RECIRCULATION: 19 (pulse) FRESH: 7 (pulse) | - |
| Electric Heater Count*1 | Maximum heater operation level / Min.: 0 Max.: 3 | Maximum possible operation level of quick heater assembly displayed | - |
| Electric Heater Active Level*1 | Actual heater operation level / Min.: 0 Max.: 2 | Actual operation level of quick heater assembly displayed | - |
| Compressor Speed | Compressor speed / Min.: 0 rpm Max.: 65535 rpm | Displays actual rotation speed in the range between 0 rpm and 10000 rpm | - |
| Compressor Target Speed | Compressor target speed / Min.: 0 rpm Max.: 65535 rpm | Displays actual rotation speed in the range between 0 rpm and 10000 rpm | - |
| Shift Set Temperature | Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode*3 | Air inlet mode / Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode / Auto or Manual | Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction / OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | ECO MODE Cancel / OFF or ON | Customized value displayed | - |
| ECO Switch | ECO MODE switch / OFF or ON | OFF: ECO MODE switch off ON: ECO MODE switch on | - |
| Foot/DEF Auto Mode | Foot/DEF Auto Mode / ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF Auto blower speed increase / ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| Compressor Drive Check | Compressor drive check / OK or NG | NG: Compressor does not drive OK: Compressor drives | - |
| Solar Ventilation Switch*2 | Solar ventilation switch (switch recognition value at A/C amplifier side) / OFF or ON | OFF: Solar ventilation switch off ON: Solar ventilation switch on | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 | Number of DTCs displayed | - |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Hood Courtesy SW*4 | Engine hood courtesy signal / OFF or ON | ON: Engine hood open OFF: Engine hood closed | - |
| ACTIVE TEST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 10000 | - |
| Water Pump | Engine water pump | OFF or ON | - |
| Electrical Fan | Electrical fan | OFF or ON | - |
| Heater Active Level*1 | Heater active level | Min.: 0, Max.: 3 | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF or ON | - |
| Mirror Heater Relay (Front) | Mirror heater relay (Front) | OFF or ON | - |
| Air Mix Servo Targ Pulse(D) | Air mix servo motor pulse | Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) | Air outlet servo motor pulse | Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 0, Max.: 255 | - |