PURGE VALVE > INSPECTION |
| 1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
Check operation of the vacuum switching valve assembly.
![]() |
Blow air into port E. Check that air does not come out of port F.
| *1 | Port F |
| *2 | Port E |
| *3 | Air Blow |
![]() |
Apply battery voltage across the terminals.
| *1 | Port F |
| *2 | Port E |
| *3 | Air Blow |
Blow air into port E. Check that air comes out from port F.
If the result is not as specified, replace the vacuum switching valve assembly.