Home › Drivetrain › P410 HYBRID TRANSMISSION / TRANSAXLE › ELECTRONIC SHIFT LEVER SYSTEM

ELECTRONIC SHIFT LEVER SYSTEM > TERMINALS OF ECU

for Preparation Click here



TRANSMISSION CONTROL ECU INSPECTION

C208988E02

HINT:
Inspect the connectors from the back while the connector is connected.


Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
A23-1 (MWA) - A24-6 (E01)
W - W-B
Parking lock motor
Engine stopped (hybrid system stopped), power switch on (IG)
9 to 14 V
A23-2 (MVA) - A24-6 (E01)
R - W-B
Parking lock motor
Engine stopped (hybrid system stopped), power switch on (IG)
9 to 14 V
A23-5 (MUA) - A24-6 (E01)
B - W-B
Parking lock motor
Engine stopped (hybrid system stopped), power switch on (IG)
9 to 14 V
A23-7 (VC) - A23-19 (E2)
G - P
Power source (Rotation angle sensor)
Engine stopped (hybrid system stopped), power switch on (IG)
4.5 to 5.5 V
A23-8 (RB) - A23-19 (E2)
GR - P
Rotation angle sensor signal
Power switch off → Power switch on (IG)
0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG)
Changing from park (P) to neutral (N), or neutral (N) to park (P).
Pulse generation
(see waveform 1)
A23-15 (BATT) - A24-1 (E1)
SB - BR
Power source (RAM)
Always
9 to 14 V
A23-16 (+B) - A24-1 (E1)
L - BR
Power source
Engine stopped (hybrid system stopped), power switch on (IG)
9 to 14 V
A23-17 (RA) - A23-19 (E2)
LG - P
Rotation angle sensor signal
Power switch off → Power switch on (IG)
0 to 1.5 V ←→ 4 to 5.5 V
Power switch on (IG)
Changing from park (P) to neutral (N), or neutral (N) to park (P).
Pulse generation
(see waveform 1)
A23-19 (E2) - Body ground
P - Body ground
Rotation angle sensor ground
Always
Below 1 Ω
A23-20 (IND) - A24-1 (E1)
R - BR
P position switch indicator light
Park (P) not selected → Park (P) selected [P position switch (transmission shift main switch) pushed to select park (P)]
9 to 14 V → 0 to 1.5 V
A23-23 (BMA) - A24-1 (E1)
B - BR
P CON MTR relay (transaxle parking lock control relay)
Engine stopped (hybrid system stopped), power switch on (IG)
9 to 14 V
A24-1 (E1) - Body ground
BR - Body ground
Ground
Always
Below 1 Ω
A24-5 (E02) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
A24-6 (E01) - Body ground
W-B - Body ground
Ground
Always
Below 1 Ω
A24-15 (CA1L) - A24-1 (E1)
BR - BR
CAN communication
Power switch on (IG)
Pulse generation
(see waveform 2)
A24-16 (CA1H) - A24-1 (E1)
Y - BR
CAN communication
Power switch on (IG)
Pulse generation
(see waveform 2)
A24-22 (PCON) - A24-1 (E1)
LG - BR
Communication bus
Engine stopped (hybrid system stopped), power switch on (IG)
Pulse generation
(see waveform 3)
A24-23 (PPOS) - A24-1 (E1)
W - BR
Communication bus
Engine stopped (hybrid system stopped), power switch on (IG)
Pulse generation
(see waveform 3)
A24-24 (LIN)
L
LIN communication
-
-

Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    C231275E01
  1. Waveform 1 (Rotation angle sensor signal)
    Item
    Contents
    Terminal
    A23-17 (RA) - A23-19 (E2)
    A23-8 (RB) - A23-19 (E2)
    Equipment setting
    2 V/DIV., 100 msec./DIV.
    Condition
    Power switch on (IG)
    Changing from park (P) to neutral (N), or neutral (N) to park (P).

    HINT:
    1. When changing from park (P) to neutral (N), or neutral (N) to park (P) with the power switch on (IG), a waveform will be generated for up to 0.5 seconds.
    2. The waveform shown is for reference only.



  2. A111598E03
  3. Waveform 2 (CAN communication signal)
    Item
    Contents
    Terminal
    CH1: A24-16 (CA1H) - A24-1 (E1)
    CH2: A24-15 (CA1L) - A24-1 (E1)
    Equipment setting
    1 V/DIV., 50 μs/DIV.
    Condition
    Power switch on (IG)



  4. C236203E01
  5. Waveform 3 (Transmission control communication signal)
    Item
    Contents
    Terminal
    CH1: A24-22 (PCON) - A24-1 (E1)
    CH2: A24-23 (PPOS) - A24-1 (E1)
    Equipment setting
    10 V/DIV., 10 ms/DIV.
    Condition
    Engine stopped (hybrid system stopped), power switch on (IG)