DTC P0A80-123 Replace Hybrid Battery Pack |


| DTC No. | DTC Detection Condition | Trouble Area |
| P0A80-123 | Voltage difference between battery blocks is larger than the specified value due to an internal malfunction of the HV battery. (2 trip detection logic) |
|
| DTC No. | Data List |
| P0A80-123 |
|
| Related DTCs | P0A80 (INF 123): Rationality |
| Required sensors / components | Main: Battery voltage sensor inside battery smart unit Sub: Battery current sensor, battery temperature sensor |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | TMC's intellectual property |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Battery smart unit | DTC P0A80 (INF 123) is not detected |
| 1.CHECK DTC OUTPUT (DTC P0AFC-123 IS OUTPUT) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check and record any HV system DTCs, INF codes and freeze frame data.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Disconnect the Techstream from the DLC3.
|
| ||||
| A | |
| 2.CHECK BATTERY SMART UNIT |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
Using the Techstream, make a note of the freeze frame data item "Battery Block Vol -V01 to V14".
Compare the freeze frame data item "Battery Block Vol -V01 to V14" values with those shown in the following combination tables.
| Circuit A Battery Block | Circuit B Battery Block | Condition |
| Battery Block Vol - V01 (VB1) | Battery Block Vol - V02 (VB2) | "Battery Block Vol - V01" - "Battery Block Vol - V02" = 0.3 V or more |
| Battery Block Vol - V04 (VB4) | Battery Block Vol - V03 (VB3) | "Battery Block Vol - V04" - "Battery Block Vol - V03" = 0.3 V or more |
| Battery Block Vol - V05 (VB5) | Battery Block Vol - V06 (VB6) | "Battery Block Vol - V05" - "Battery Block Vol - V06" = 0.3 V or more |
| Battery Block Vol - V08 (VB8) | Battery Block Vol - V07 (VB7) | "Battery Block Vol - V08" - "Battery Block Vol - V07" = 0.3 V or more |
| Battery Block Vol - V09 (VB9) | Battery Block Vol - V10 (VB10) | "Battery Block Vol - V09" - "Battery Block Vol - V10" = 0.3 V or more |
| Battery Block Vol - V12 (VB12) | Battery Block Vol - V11 (VB11) | "Battery Block Vol - V12" - "Battery Block Vol - V11" = 0.3 V or more |
| Battery Block Vol - V13 (VB13) | Battery Block Vol - V14 (VB14) | "Battery Block Vol - V13" - "Battery Block Vol - V14" = 0.3 V or more |
| Circuit A Battery Block | Circuit B Battery Block | Condition |
| Battery Block Vol - V01 (VB1) | Battery Block Vol - V02 (VB2) | "Battery Block Vol - V02" - "Battery Block Vol - V01" = 0.3 V or more |
| Battery Block Vol - V04 (VB4) | Battery Block Vol - V03 (VB3) | "Battery Block Vol - V03" - "Battery Block Vol - V04" = 0.3 V or more |
| Battery Block Vol - V05 (VB5) | Battery Block Vol - V06 (VB6) | "Battery Block Vol - V06" - "Battery Block Vol - V05" = 0.3 V or more |
| Battery Block Vol - V08 (VB8) | Battery Block Vol - V07 (VB7) | "Battery Block Vol - V07" - "Battery Block Vol - V08" = 0.3 V or more |
| Battery Block Vol - V09 (VB9) | Battery Block Vol - V10 (VB10) | "Battery Block Vol - V10" - "Battery Block Vol - V09" = 0.3 V or more |
| Battery Block Vol - V12 (VB12) | Battery Block Vol - V11 (VB11) | "Battery Block Vol - V11" - "Battery Block Vol - V12" = 0.3 V or more |
| Battery Block Vol - V13 (VB13) | Battery Block Vol - V14 (VB14) | "Battery Block Vol - V14" - "Battery Block Vol - V13" = 0.3 V or more |

| Result | Proceed to |
| All conditions in table 1 are met. | A |
| All conditions in table 2 are met. | |
| Other than above | B |
Turn the power switch off.
|
| ||||
| A | ||
| ||