Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A94-556    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

For a description of the boost converter .
If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU (HV CPU).

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
556
Boost converter fail signal detection (overcurrent by hybrid vehicle transaxle assembly malfunction)*
(1 trip detection logic)
  1. Wire harness or connector
  2. Inverter with converter assembly
  3. Hybrid vehicle transaxle assembly
*: Hybrid vehicle transaxle assembly may be suspected as a main case of the malfunction.

MONITOR DESCRIPTION

If excessive amperage flows through the boost converter due to an internal short, the boost converter will transmit a boost converter fail signal to the MG ECU. Upon receiving this signal, the power management control ECU (HV CPU) will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A94 (INF 556): FCV detection (Over current malfunction)
Required sensors / components
Boost converter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU (HV CPU)
DTC P0A94 (INF 556) is not detected

CONFIRMATION DRIVING PATTERN


A308311E02

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 30 seconds or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. Turn the power switch on (READY).
  7. With park (P) selected, wait for 5 seconds. [A]
  8. With the engine stopped and park (P) selected, depress the accelerator pedal to start the engine. [B]
  9. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  10. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  11. Check that permanent DTCs are cleared.
  12. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 5 seconds or more.
  2. With the engine stopped and park (P) selected, depress the accelerator pedal to start the engine.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    DTC P0A94-556 only is output or DTCs other than the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72 (all INF codes)*1
    Generator Phase V Current
    P0A75 (all INF codes)*1
    Generator Phase W Current
    P0A78-266, 267, 287, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-325, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A94-585, 587, 589, 590
    DC / DC Converter Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A94-556 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
A214648

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

  1. Check the connection of the low voltage connector of the inverter with converter assembly.

    OK:
    The connector is connected securely and there are no contact problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


3.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-12 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-7 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-8 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-10 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-9 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the low voltage connector from the inverter with converter assembly.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK GENERATOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - D29-12 (GRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-7 (GSN) - D29-8 (GSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-10 (GCS) - D29-9 (GCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 9
OK


5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-2 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-3 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-4 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-6 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-5 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK MOTOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - D29-2 (MRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-3 (MSN) - D29-4 (MSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-6 (MCS) - D29-5 (MCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 11
OK


7.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


8.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

9.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217748E01
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) - D29-11 (GRF)
    Power switch off
    Below 1 Ω
    D7-5 (GRFG) - D29-12 (GRFG)
    Power switch off
    Below 1 Ω
    D7-2 (GSN) - D29-7 (GSN)
    Power switch off
    Below 1 Ω
    D7-6 (GSNG) - D29-8 (GSNG)
    Power switch off
    Below 1 Ω
    D7-3 (GCS) - D29-10 (GCS)
    Power switch off
    Below 1 Ω
    D7-7 (GCSG) - D29-9 (GCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) or D29-11 (GRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-5 (GRFG) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-2 (GSN) or D29-7 (GSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-6 (GSNG) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-3 (GCS) or D29-10 (GCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-7 (GCSG) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Generator Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

11.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


12.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217749E01
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) - D29-1 (MRF)
    Power switch off
    Below 1 Ω
    D1-6 (MRFG) - D29-2 (MRFG)
    Power switch off
    Below 1 Ω
    D1-1 (MSN) - D29-3 (MSN)
    Power switch off
    Below 1 Ω
    D1-4 (MSNG) - D29-4 (MSNG)
    Power switch off
    Below 1 Ω
    D1-2 (MCS) - D29-6 (MCS)
    Power switch off
    Below 1 Ω
    D1-5 (MCSG) - D29-5 (MCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) or D29-1 (MRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-6 (MRFG) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-1 (MSN) or D29-3 (MSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-4 (MSNG) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-2 (MCS) or D29-6 (MCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-5 (MCSG) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Motor Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)