Home › Engine / Hybrid System › 2ZR-FXE ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > ECM Power Source Circuit

for Preparation Click here


DESCRIPTION

When the power switch is turned on (IG), auxiliary battery voltage is applied to IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI MAIN relay) and supplying power to terminals +B and +B2 of the ECM.

WIRING DIAGRAM


A217616E04


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    D28-104 (E1) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.INSPECT ECM (IGSW VOLTAGE)


    A194151E64
  1. Disconnect the ECM connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A57-28 (IGSW) - Body ground
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)



NG
Go to step 7
OK


3.INSPECT INTEGRATION RELAY (EFI MAIN RELAY)
  1. Inspect the integration relay (Click here).



NG
REPLACE INTEGRATION RELAY (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (EFI MAIN RELAY) - ECM)
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1B-4 - A57-1 (+B2)
    Always
    Below 1 Ω
    1B-4 - A57-2 (+B)
    Always
    Below 1 Ω
    1B-2 - A57-6 (MREL)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (EFI MAIN RELAY) - AUXILIARY BATTERY)
  1. Disconnect the negative (-) auxiliary battery terminal.

  1. Disconnect the positive (+) auxiliary battery terminal.

  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1C-1 - Auxiliary battery positive terminal
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (EFI MAIN RELAY) - BODY GROUND)
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    1B-3 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

7.INSPECT INTEGRATION RELAY (IG2 RELAY)
  1. Inspect the integration relay (Click here).



NG
REPLACE INTEGRATION RELAY (Click here)
OK


8.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (IG2 RELAY) - ECM)
  1. Disconnect the ECM connector.

  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1A-4 - A57-28 (IGSW)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (IG2 RELAY) - AUXILIARY BATTERY)
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Disconnect the negative auxiliary battery terminal.

  1. Disconnect the positive auxiliary battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1C-1 - Auxiliary battery positive terminal
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY (IG2 RELAY) - BODY GROUND)
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    1A-3 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INTEGRATION RELAY (IG2 RELAY))
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Disconnect the power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    A22-2 (IG2D) - 1A-2
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK SMART KEY SYSTEM (Click here)